Gas Sensor Modules

Specifications

Gas Type

Model

Sensor

Range

Units

Resolution

Response Sensor

Operating Range

 

 

 

 

 

 

 

 

Time (1)

Life (2)

oF

oC

RH

Combustibles

4101-02

Catalytic

0-100

%LEL

+/-3% F.S.

(3)

3 Yrs

-40 to 167

-40 to 75

10

- 95%

Oxygen

4101-03EL EC

0-25

% Vol +/-0.1%

<10 sec.

2 Yr

5 to 122

-15 to 50

5 - 99%

Carbon Monoxide

4101-04

EC

0-500

PPM

1.0 PPM

<25 sec

2 Yrs

-4 to 122

-20 to 50

15 – 90%

Hydrogen Sulfide

4101-05

EC

0-100

PPM

0.1 PPM

<30 sec

2 Yrs

-40 to 122

-40 to 50

15 – 90%

Chlorine

4101-06

EC

0-10

PPM

0.1 PPM

<60 sec

2 Yrs

-4 to 122

-20 to 50

15 – 90%

Sulfur Dioxide

4101-10

EC

0-100

PPM

0.5 PPM

<20 sec

2 Yrs

-4 to 122

-20 to 50

15 – 90%

Nitrogen Dioxide

4101-12

EC

0-20

PPM

0.2 PPM

<35 sec

2 Yrs

-4 to 122

-20 to 50

15 – 90%

Carbon Monoxide 4

4101-13

EC

0-1000

PPM

0.5 PPM

<35 sec

2 Yrs

-4 to 122

-20 to 50

15 – 90%

Carbon Monoxide

4101-16

EC

0-2000

PPM

0.1 PPM

<35 sec

2 Yrs

-4 to 122

-20 to 50

15 – 90%

Nitric Oxide

4101-19

EC

0-20

PPM

0.5 PPM

<15 sec

3 Yrs

-4 to 122

-20 to 50

15 – 90%

Hydrogen Chloride

4101-21

EC

0-20

PPM

0.1 PPM

<100 sec

2 Yrs

-4 to 122

-20 to 50

15 – 90%

Hydrogen Cyanide

4101-22

EC

0-20

PPM

0.1 PPM

<70 sec

2 Yrs

-4 to 122

-20 to 50

15 – 90%

Ammonia

4101-25

EC

0-50

PPM

1.0 PPM

<30 sec

(5)

14 to 113

-10 to 45

20 – 95%

Hydrogen Fluoride

4101-26

EC

0-10

PPM

1.0 PPM

<30 sec

(5)

14 to 113

-10 to 45

20 – 95%

Ethylene Oxide

4101-27

EC

0-20

PPM

0.1 PPM

<90 sec

2 Yrs

-4 to 122

-20 to 50

15 – 90%

Notes: (1) Response time to 90% full signal value for applied concentration

(2)Sensor life typical for use at standard temperature and pressure with occasional exposure to gas of interest

(3)Step to 50% LEL within 10 seconds. Recovery to 10% LEL within 30 seconds

(4)Hydrogen tolerent

(5)Diffusion via membrane. Requires electrolyte and membrane replacement every 6 months.

Electrical Data

 

Construction

 

 

Loop Type

3 wire

Modules

Dimensions

Weight

Loop Resistance

800 Ohm with 28VDC

4101-02

H: 7.5", D: 4.0", W: 4.0"

2.0 lb

 

400 Ohms at 21 VDC (4101-02)

 

(21.6 x 10.2 x 10.2 cm)

(0.9 Kg)

Input Voltage DC

14-30 VDC (20-30VDC 4101-02)

4101-03EL

H: 8.5", D: 4.0", W: 4.0"

2.1 lb

Input Current

40 mA (80 mA 4101-02)

 

(21.6 x 10.2 x 10.2 cm)

(1.0 Kg)

Input Power Max

1.4W (2.3W 4101-02)

4101-04-27

H: 8.0", D: 4.5", W: 4.0"

2.7 lb

Signal Output

4-20 mA DC linear (trouble 0 mA)

 

(20.3 x 15.2 x 15.2 cm)

(1.3 Kg)

Operating Pressure

+10% (variation from ambient)

4101-25/26

H: 10.2", D: 6.0", W: 6.0"

2.7 lb

 

 

 

(25.9 x 15.2 x 15.2 cm)

(1.3 Kg)

Cross Sensitivity Data

 

Model

Gas

 

 

Reading

from 100 PPM of interfering gas

 

 

 

 

 

 

 

 

Number

type

CO

H2S

Cl2

H2

SO2

NO2

NO

 

HCl

HCN

C2H4

 

 

 

4101-04

CO

100

5

0

<20

0

0

6

 

0

0

<50

 

4101-05

H2S

<2

100

-20

<0.1

<15

-15

0

 

0

0

0

 

4101-06

Cl2

0

<-10

100

0

0

105

0

 

0

0

0

 

4101-10

SO2

<1

0

-40

0

100

-100

0

 

0

15

0

 

4101-12

NO2

0

-20

90

0

0

100

0

 

0

-3

0

 

4101-13

CO

100

350

0

<60

60

-60

25

 

0

0

<75

 

4101-16

CO

100

0

0

0

0

0

0

 

0

0

35

 

4101-19

NO

0

35

0

0

5

25

100

 

15

0

0

 

4101-21

HCl

0

75

-10

0

35

-2

0

 

100

-8

0

 

4101-22

HCN

<0.5

 

-50

0

160

-190

-5

 

 

100

<1

 

4101-27

C2H4O

Ethanol

 

55

 

 

 

 

 

 

 

 

 

 

 

 

 

(ETO)

Toluene

 

20

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Methyl-ethyl-ketone

10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Carbon Monoxide

40

4101-02 Combustible Gas Sensor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

is FM Approved

 

 

 

 

 

 

 

 

05/04

Sierra Monitor Corp. 1991 Tarob Ct., Milpitas, CA 95035, USA, 408-262-6611, 800-727-4377, FAX: 408-262-9042

Web Site: http://www.sierramonitor.com E-Mail: sierra@sierramonitor.com

© 2004 by Sierra Monitor Corporation

Page 2
Image 2
Sierra Monitor Corporation 4101 manual Gas Sensor Modules, Cross Sensitivity Data

4101 specifications

Sierra Monitor Corporation (SMC), renowned for its innovative solutions, introduced the Model 4101 as part of its advanced line of products aimed at improving industrial automation and safety. The 4101 model is a sophisticated communication device designed to facilitate seamless interaction between various industrial control systems.

One of the standout features of the Sierra Monitor 4101 is its ability to support multiple communication protocols, including Modbus RTU, Modbus TCP/IP, and BACnet, enabling it to interface with a wide array of devices and systems. This versatility allows for easy integration into existing infrastructures, making it highly adaptable for different environments.

The 4101 is equipped with a powerful microprocessor that ensures reliable performance and quick data processing. Its robust hardware is designed to withstand harsh industrial conditions, including extreme temperatures and vibrations, which is critical for field applications. This reliability extends to its power supply options, as the model can operate on standard AC or DC power sources.

Security is a primary concern in today’s industrial landscape, and the Sierra Monitor 4101 addresses this with built-in cybersecurity measures. These include secure firmware updates and encrypted communications, helping to protect sensitive data from unauthorized access and cyber threats.

An additional feature of the 4101 is its user-friendly interface, which simplifies setup and configuration. This allows technicians to carry out installation and maintenance tasks swiftly, minimizing downtime. The device is also equipped with LED indicators for status monitoring, providing real-time feedback on connectivity and operational status.

Another key characteristic of the Sierra Monitor 4101 is its scalability. It is designed to grow alongside your business, making it feasible for both smaller operations and larger industrial complexes. This scalability is complemented by the device's ability to support multiple connections simultaneously, ensuring that it can handle the demands of extensive data transactions.

In summary, the Sierra Monitor Corporation 4101 combines advanced communication capabilities, robust hardware, enhanced security, and user-friendly design, making it an invaluable asset for modern industrial applications. Whether in energy management, building automation, or process control, the 4101 provides the necessary tools to optimize operations and ensure safety in diverse industrial settings.