Sierra Products EasyFire B manual Other related operating parameters

Models: EasyFire B

1 4
Download 4 pages 39.16 Kb
Page 1
Image 1
Other related operating parameters

EasyFire B Model Pellet Heater Quick Troubleshoot and Technical Guide

SPI’s EasyFire pellet heaters are designed to operate as a seasonal zone heater burning 1/4" wood pellet fuel. Utilizing a 12VDC control and drive system allows for extended battery operation when AC power fails. The following outlines the general operating param eters and trouble shooting encountered during installation and seasonal operation. Basic operation is controlled com bustion of wood pellets metered by the feed drive system into a burn pot and a

com bustion/convection fan motor providing separate air for combustion and heat exchange. This process is controlled by a digital main controller which monitors all function through two sensors and incoming outgoing operating voltages. Additionally, starting functions are provided by an industrial style cartridge heater located in the burn pot and both internal and optional therm ostat.

Standard operation: W ith both 120VAC and 12VDC battery power attached and a functional pellet flue system the heater is designed to operate continuously during the heating season. On a daily bases the heater requires fuel to be added to the storage hopper and depending on the fuel quality, burn pot area cleaned. Starting and operating sequences are controlled by an operating software program contained on a EPROM mem ory chip. Fuel rate is controlled by mode setting and trim position (standard trim knob setting is 9:00 and is located on control panel next to operation buttons). Norm al start up and operation sum m ary follows:

Condition - Heater is cold, power connected, button to “OFF” position. Hopper door closed (safety switch closed). External therm ostat jum ped (factory standard) or optional therm ostat closed to call for heat.

1)Select a run button (Low, Medium , High) and press. The LED light will shift from OFF to run button.

A)Feed motor starts initial fuel shot (approx. 40 seconds) and ignitor ON. Ignitor will begin to start heating and pass 300 degrees in 30 seconds.

B)Fan motor starts in 60 seconds @ 3 volts providing com bustion and convection air. Feed will cycle OFF com pleting the start up fuel shot. Sm oke will be visible norm ally visible through the door glass with in 2 m inutes.

C)Feed will cycle ON for short periods during the start cycle add sm all am ounts of fuel. Heater continue in START UP m ode until tem perature rise is confirm ed by sensors or for a total of 10 m inutes.

If tem perature does not increase by 15C during this STARTUP phase the heater will begin the SHUTDOW N (for further information read SHUTDOW N in several paragraphs).

2)RUN mode begins when tem perature rise is achieved (normally within 5-7 minutes).

A)Fan increases based on run button selected. Feed pulses increase based on tem perature and TRIM setting. Feed trim adjustm ent allows for a lower or higher average fuel delivery.

Initial flam e is high based on a cool heater and fuel shots provided for start up. As operating tem perature is reached the feed pulse will decrease and flam e will drop.

B)Feed rate will vary up and down as the heater adjusts for operating tem perature. Tem perature measured at T- 2 sensor mounted on fan housing manifold.

C)Heater will continue to operate as long as fuel, therm ostat setting, and operating button rem ains.

Condition - Shutting down operating heater. Selecting the OFF button or external therm ostat no longer calls for heat.

A)Feed motor im m ediately stops. No fuel is added to the burn pot and the coals rem aining began the burn out.

B)Fan is reduced to shut off voltage of 5 volts and maintained until sensor T-2 records a 20C reduction of tem perature or 20 m inutes tim e elapses.

Other related operating parameters

Three basic functions are constantly monitored during operation including flue drafting, operating tem peratures, and AC power input. Blocked flue will cause an unsafe condition and will cause the unit to shut down with a steady RED fault indication noted on the control panel. Continued high tem perature may cause a unsafe condition. The heater will

1

Page 1
Image 1
Sierra Products EasyFire B manual Other related operating parameters