DAILY INSPECTION INSTRUCTIONS
Operational features 1 Source assembly
A sealed source containing the radioactive material is swaged (crimped) to one end of a flexible steel leader, commonly referred to as the source holder or pigtail. A steel
DANGER - IMPORTANT WARNING
The source assembly while in an unshielded position and the sealed source containing the radioactive material must NOT be handled under any circumstances. The unshielded source at close proximity can cause serious injury, sickness or death to anyone exposed to it even for a short duration.
All specific model number source assemblies used in the Model 880 are designed and tested for use in accordance to ISO/ANSI and USNRC requirements.
2 Exposure device
The source assembly is shown in the stored position in a titanium ‘S’ tube at the center of the depleted Uranium shield of the exposure device. (See figure 3.2)
A remote control unit is shown with its control cable connector coupled to the source assembly.
High density depleted Uranium shielding is used in the exposure device to provide good radiological protection with minimal weight.
Sealed source | Flexible leader | Stop ball |
| Control cable | ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Source assembly | Control cable | ||||||
connector | connector | ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Figure 3.1 Source assembly and remote control cable connectors
3.2