INSTALLATION AND OVERVIEW GENERAL OPERATING REQUIREMENTS 
ENVIRONMENTAL 
Ambient temperature/Ventilation 
The MRX Switching System is designed to operate as specified when the ambient temperature is kept 
within the range of 0°C to 50°C.  Ventilation slots are provided on the front and sides of the frames to assist 
in the removal of the excess heat generated in the normal operation of the units.  These ventilation slots 
must not be blocked.  Sigma Electronics will consider blocking of these slots, to be a custom, design 
modification by the user.  Custom design modifications void the Sigma Electronics warranty. 
Humidity 
Excessive humidity is harmful to electronic equipment. It is expected that the user will monitor and control 
the relative humidity of the operating environment to maintain levels acceptable for the operation of this 
equipment. 
Rack-mounting 
All frames and control panels are intended to be mounted in standard 19” EIA equipment r acks. Prior to 
installing an MRX Series frame into a rack, the f ront panel must be removed. To remove the front  panel, 
grasp the handles and pull firmly away from the frame.  The f ront panel should complet ely detach from t he 
ballstuds. 
Audio Frame placement 
Due to the susceptibility of all audio circuitry to interference from power sources, the audio frame should be 
located as far away from power sources as possible.   
POWER 
The MRX Switching System is designed to operate in all standard commercial power environments 
providing input voltage between 100VAC and 240VAC ± 10%.  Voltages outside of this range may or may 
not be tolerated by the equipment for a period of time but will, in any case, be considered a violation of the 
warranty.