DESCRIPTION

This Submersible Sump Pump is designed for home sumps. Unit is equipped with a 3-prong grounding-type power cord. Motor is sealed for cooler running. Bearings on motor shaft never need lubrication. Automatic reset thermal protection. Not designed for use as a swimming pool drainer.

SPECIFICATIONS

Power supply required

...........................115V, 60 HZ.

Liquid Temp. Range

32°F to 95°F(0°-35°C)

Minimum Water Level when pump is operating ...5.5"

Max. Submergence Level

23'

Individual Branch Circuit Required (min.)

....15 Amps

Discharge

1-1/2" FNPT

NOTICE: Do not reduce size of discharge pipe or hose below 1-1/4" diameter. If discharge is too small, pump will overheat and fail prematurely.

This pump is designed for use in a residential sump only. Pump water only with this pump.

NOTICE: This unit is not designed as a waterfall or foun- tain pump, or for applications involving salt water or brine! Use with waterfalls, fountains, salt water or brine will void warranty.

NOTICE: Pump can pump down to about 1/4" (6 mm), but should not be allowed to run for a period of time unless it is in at least 5-1/2" of water.

Do not use where water recirculates.

Not designed for use as a swimming pool drainer.

PERFORMANCE

GPH (LPH) AT TOTAL FEET (M) OF LIFT

 

 

0

10

20

25

No flow

Model

HP

(0m)

(3m)

(6m)

(7.6m)

at height

 

 

 

 

 

 

shown

 

 

CAPACITY GALLONS(L)/HOUR

 

 

below

 

 

 

 

 

 

12558

1/3

2880

2460

1800

1200

28'

(10,902)

(9,312)

(6,814)

(4,542)

(8.5m)

 

 

 

 

 

 

 

 

 

12356

1/2

3180

2700

2040

1500

30'

(12,037)

(10,220)

(7,722)

(5,678)

(9.1m)

 

 

 

 

 

 

 

 

 

ELECTRICAL & SWITCH SPECIFICATIONS

 

 

Individual

 

 

 

 

Branch

Switch Setting

 

 

Circuit

in inches (mm)

Model

HP

Req.(Amps)

On

Off

12558

1/3

15

13.5"(330)

5.5"(140)

12356

1/2

15

14.0"(356)

6.0"(152)

GENERAL SAFETY INFORMATION

Electrically powered sump pumps normally give many years of trouble-free service when correctly installed, maintained, and used. However, unusual circumstances (interruption of power to the pump, dirt/debris in the sump, flooding that exceeds the pump’s capacity, electrical or mechanical failure in the pump, etc.) may prevent your pump from func- tioning normally. To prevent possible water damage due to flooding, consult your retailer about a sec- ondary AC sump pump, a DC backup sump pump, and/or a high water alarm. See the “Troubleshooting Chart” in this manual for information about common sump pump problems and remedies. For more infor- mation, see your retailer, call Simer customer service at 1-800-468-7867 / 1-800-546-7867.

1.Know the pump application, limitations, and potential hazards.

2.Do not use in water with fish present. If any oil leaks out of the motor it can kill fish.

3.Disconnect power before servicing.

4.Release all pressure within system before servic- ing any component.

5.Drain all water from system before servicing.

6.Secure discharge line before starting pump. An unsecured discharge line will whip, possibly causing personal injury and/or property damage.

7.Check hoses for weak or worn condition before each use, making certain that all connections are secure.

8.Periodically inspect sump, pump and system components. Keep free of debris and foreign objects. Perform routine maintenance as required.

9.Provide means of pressure relief for pumps whose discharge line can be shut-off or obstructed.

10.Personal Safety:

a.Wear safety glasses at all times when working with pumps.

b.Keep work area clean, uncluttered and prop- erly lighted – replace all unused tools and equipment.

c.Keep visitors at a safe distance from work area.

d.Make workshop child-proof – with padlocks, master switches, and by removing starter keys.

11.When wiring an electrically driven pump, follow all electrical and safety codes that apply.

12.This equipment is only for use on 115 volt (single phase) and is equipped with an approved 3-conductor cord and 3-prong, grounding-type plug.

For assistance, call Simer Customer Service at 1-800-468-7867 /1-800-546-7867