501 Insulation Tester

The model 501 can be used for general purpose insulation tests that require voltages from 50V to 1000V only.

The Instrument is equipped with AC and DC measuring ranges up to 1000V. This is advantageous for testing for the absence of voltage and the discharge of capacitive devices under test.

The 501 features a quick testing signal lamp within the test probe that illuminates the work area. The signal lamp can also be used for quick Pass/Fail evaluations of insulation resistances. Minimum values for insulation resistances are present if the lamp lights up.

Comes equipped with built-in test probes, an alligator clip, a leatherette carrying case and batteries.

Five Test Voltages: 50, 100, 250, 500, and 1000 VDC

Voltage Measurement to 1000 V AC/DC

Test Probe Signal Lamp Illuminates Work Area and Indicates Pass/Fail of Insulation Resistance

Battery Powered with Battery Test and Battery Charge Indicator

Rugged Tester Design for Industrial Applications with Leatherette Carrying Case

Measuring Ranges

INSULATION RESISTANCE

Measuring

 

 

 

 

 

 

 

Lamp in Test Prod 1)

Range

Open-Circuit Voltage

Uo

Internal Resistance R i

 

Lights for Resistance

0…50KΩ

 

 

 

 

30KΩ

 

 

> 100KΩ

20KΩ…1MΩ

60V

 

 

10KΩ

 

 

 

200KΩ…20MΩ

 

 

 

 

40KΩ

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0…100KΩ

 

 

 

 

60KΩ

 

 

> 200KΩ

40KΩ…2MΩ

120V

 

 

20KΩ

 

 

 

400KΩ…40MΩ

 

 

 

 

80KΩ

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0…250KΩ

 

 

 

 

150KΩ

 

 

> 500KΩ

100KΩ…5MΩ

300V

 

 

50KΩ

 

 

 

1MΩ…100MΩ

 

 

 

 

200KΩ

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0…500KΩ

 

 

 

 

300KΩ

 

 

> 1MΩ

200KΩ…10MΩ

600V

 

 

100KΩ

 

 

 

2MΩ…200MΩ

 

 

 

 

400KΩ

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0…1MΩ

 

 

 

 

600KΩ

 

 

> 2MΩ

400KΩ…20MΩ

1200V

 

 

200KΩ

 

 

 

4MΩ…400KΩ

 

 

 

 

800KΩ

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0…4KΩ

9V

 

 

-

 

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(1) Switching Accuracy

DIRECT AND ALTERNATING CURRENT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Measuring

 

 

 

Internal

 

Maximam

 

 

Range

 

Frequency

 

Resistance

 

Overload

 

Intrinsic Error (1)

0 to 1000V

 

0 or 40 to 200Hz

 

900KΩ

 

1200V AC/DC

 

±2.5%

AC/DC

 

 

 

 

 

 

Continuous

 

 

 

 

 

 

 

 

 

 

 

(1) Referring to scale length

Ordering Information

ACCESSORIES

Catalog No.

501 Insulation Tester, 1000 V

12501

 

 

Specifications

REFERENCE CONDITIONS

Ambient Temperature: 73°F (23°C) ± 4°F (2°C)

Relative Humidity: 45 to 55%

Measurement Magnitude Frequency: 45-65 Hz (voltage measurements)

Line Voltage Waveform: Sine, deviation between effective and rectified value < .5%

Battery Voltage: 9V ± .5V

Operating Position: Horizontal

ELECTROMAGNETIC COMPATIBILITY EMC

Interference Emission:

EN 50081-1: 1992

Interference Immunity:

EN 50082-1: 1992

ELECTRICAL SAFETY

Designed to IEC 1010-1

Protection Class: II

Test Voltage: 5.55Kv

Overvoltage Classification: II

Pollution Degree: 2

Protection: Housing IP52

AMBIENT CONDITIONS

Operating Temp. Range: 32°F (0°C) to 104°F (40°C)

Storage Temp. Range: -4°F (-20°C) to 140°F (60°C) (without batteries)

Relative Humidity: Max. 45-55%, condensation must be avoided

MECHANICAL DESIGN Dimensions: W 6.50” (165mm) x D 4.33” (110mm) x H 4.92” (125mm) Weight: 3.5 lbs. (1.6kg) (with batteries)

POWER SUPPLY

Standard or Storage Battery: 6 ea. 1.5V “D” size batteries

Working Range: 7V to 10V

Battery Service Life: Number of possible measurements with 1 set of “D” size

batteries (with lamp in test prod switched off): at least 3,000 measurements of an insulation resistance of 1MΩ (Nominal Voltage of1000 V, 5 sec. Measurement duration, switched off for 25 sec. etc.)

rev_1 11/2/04

Page 1
Image 1