![Model Comparison](/images/new-backgrounds/37434/374341x1.webp)
®
Model Comparison
RATINGS CHART – OIL BOILERS
EUTECTIC EC-20 BOILER - WATER
Type of Boiler |
|
|
|
|
|
|
Maximum Inputs |
|
|
|
|
|
|
#2 Fuel Oil GPH | 1.55 | 1.90 |
| 2.25 |
| 2.50 |
#2 Fuel Oil MBTH | 217 | 266 |
| 315 |
| 350 |
Gross Outputs MBTH |
|
|
|
|
|
|
#2 Fuel Oil | 190 | 232 |
| 258 |
| 287 |
Net Outputs MBTH |
|
|
|
|
|
|
#2 Fuel Oil | 165 | 202 |
| 224 |
| 250 |
AFUE Efficiency |
|
|
|
|
|
|
#2 Fuel Oil | 86.5% | 86.7% |
| N/A |
| N/A |
Thermal Efficiency | N/A | N/A |
| 86.5 |
| 86.4 |
Weight (pounds) | 567 | 655 |
| 741 |
| 827 |
Boiler Total Heating Surface Area (sq. ft.) | 32 | 39 |
| 46 |
| 53 |
Flue Diameter Connection (inches) | 6.0 | 7.0 |
| 7.0 |
| 7.0 |
Flue Pressure Drop ▲P (inches w.c.) | .09 | .12 |
| .14 |
| .16 |
Water Content (gallons) | 11.0 | 13.0 |
| 15.0 |
| 17.0 |
Specifications Common to all Boilers |
|
|
|
|
|
|
Maximum operating pressure: 58 psi | Maximum water temperature: 210°F | |||||
* CO2 = 13% #2 Fuel Oil |
|
|
|
|
|
|
SLANT/FIN CORPORATION, Greenvale, NY 11548 • Phone: (516)
FAX: (516)
www.slantfin.com | ©Slant/Fin Corp. 2007 |