DIMENSIONS – GAS BOILERS

®

SENTRY

 

C

Vent Damper*

 

 

Dimensions

 

 

MODEL S-34

 

Integral ￿

11/2" Supply

 

 

Draft￿

 

 

Diverter

 

193/4"

 

3/4" to air eliminating￿ system (by others)

Pressure/Temp.￿

 

Gauge

 

Blocked Vent￿

287/16"

Safety Switch

3/4"Drain

 

Rollout Safety￿

 

Switch (behind￿

A

front panel)

61/2"

B

High Limit.￿

 

Control

 

Ignition￿

 

Control

 

Circulator:￿

 

1/4" Circ. Flange￿

Sediment Trap￿

11/2" Return Tapping

 

(required)￿

Combination￿

 

 

Gas Valve￿

Ground￿

(Dotted piping￿

(gas tapping 1/2")

 

Joint Union

by others.)￿

LEFT END VIEW

FRONT VIEW

RIGHT END VIEW

C

Vent Damper*

 

Dimensions MODELS S-60 to S-150

11/2" Supply

193/4"

3/4" to air eliminating￿ system (by others)

Supply Piping￿ (by others)

Pressure/Temp.￿

 

Gauge

 

3/4" Drain

 

Rollout Safety￿

 

Switch (behind￿

A

front panel)

 

 

B

Blocked Vent￿

 

Safety Switch

 

High Limit￿

 

 

Control

 

 

Ignition￿

 

 

Control

 

 

327/16"

 

 

Circulator:￿

 

 

1/4" Circ. Flange￿

 

 

11/2" Return Tapping

 

Sediment Trap￿

 

 

(required)￿

Combination￿

 

 

Gas Valve￿

Ground￿

(Dotted piping￿

(gas tapping 1/2")

Joint Union

by others.)￿

LEFT END VIEW

FRONT VIEW

RIGHT END VIEW

C

 

Vent Damper*

 

Vent Damper*

C

 

 

Dimensions

3/4" to air eliminating￿

 

system (by others)

 

MODELS SX-150

Blocked Vent￿

High Limit￿

Safety Switch

to SX-210

 

Control

 

 

11/2"

Supply Piping￿

 

 

 

 

D

Supply

 

 

Ignition￿

 

 

 

 

 

 

(by others)

 

 

Control

 

 

 

 

 

 

 

 

 

Pressure/Temp.￿

 

287/16"

Circulator:￿

 

 

 

Gauge

 

1/4" Circ. Flange￿

 

Sediment Trap￿

 

 

 

 

11/2" Return Tapping

 

(required)￿

 

3/4" Drain

 

 

 

 

 

 

 

 

 

 

 

Rollout Safety￿

 

 

Combination￿

 

 

 

 

 

Gas Valve￿

Ground￿

 

3

Switch (behind￿

A

 

(Dotted piping￿

 

(gas tapping 1/2")

19 /4"

front panel)

 

Joint Union

by others.)￿

 

 

 

 

 

B

 

 

 

LEFT END VIEW

FRONT VIEW

RIGHT END VIEW

*Vent damper may be installed horizontally on all models with use of a common vent elbow.

 

 

 

 

 

 

 

DIMENSIONS-Inches

 

 

 

 

 

 

 

 

 

C-VENT DIAMETER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MODEL

A

B

INTEGRAL

EXTERNAL

D

 

 

 

 

 

DRAFT

DRAFT

 

 

 

 

 

NUMBER

 

 

 

 

 

 

 

DIVERTER

HOOD

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S-34

818

1458

4

_

_

 

 

 

 

 

S-60

1118

1758

4

_

_

 

 

 

 

 

S-90

1418

2058

5

_

_

 

 

 

 

 

S-120

1718

2358

6

_

_

 

 

 

 

 

S-150

2018

2658

7

_

_

 

 

 

 

 

SX-150

2018

2658

_

6

47

SLANT/FIN CORPORATION, Greenvale, NY 11548 • Phone: (516) 484-2600

SX-180

2318

2958

_

7

48316

SX-210

2618

3258

_

7

48316

FAX: (516) 484-5921In Canada: Slant/Fin LTD/LTEE, Mississauga, Ontario

 

 

 

 

 

 

 

 

 

 

 

 

www.slantfin.com

©Slant/Fin Corp. 2007

Page 1
Image 1
Slant/Fin S-60 to S-150 dimensions Model S-34, Left END View Front View Right END View, Models SX-150

S-60 to S-150 specifications

Slant/Fin is a reputable manufacturer known for producing high-efficiency heating solutions, and their S-60 to S-150 series is a prime example of innovation in residential and commercial heating. These models are designed to provide optimal comfort while maximizing efficiency, making them an excellent choice for modern heating needs.

The S-60 to S-150 series consists of a range of cast iron sectional boilers, each tailored to meet different heating demands. The S-60 model has a capacity of 60,000 BTUs, while the S-150 can deliver up to 150,000 BTUs. This variety ensures that customers can find a model suited to their specific heating requirements, whether for smaller residences or larger commercial spaces.

One of the main features of the S-60 to S-150 series is their durability. Constructed from heavy-duty cast iron, these boilers are designed to withstand the rigors of daily use and last for many years. The cast iron design not only enhances longevity but also provides superior heat retention, ensuring that rooms remain warm even after the unit cycles off.

Efficiency is another hallmark of the Slant/Fin S series. With an AFUE (Annual Fuel Utilization Efficiency) rating that meets or exceeds industry standards, these boilers operate with high efficiency, helping homeowners save on energy costs. They utilize advanced combustion technology, optimizing fuel usage while minimizing emissions.

The S-series also boasts easy serviceability, which is critical for maintenance and repair. Their modular design allows for convenient access to internal components, making it simpler for technicians to conduct routine inspections or necessary repairs with minimal disruption.

In terms of installation, the S-60 to S-150 models offer versatile placement options, accommodating various spaces thanks to their compact footprint and rear venting capability. Additionally, they are compatible with a range of heating systems, allowing for seamless integration into existing setups.

Finally, Slant/Fin is known for its commitment to customer support and warranty services. Each boiler comes with a reliable manufacturer warranty, providing peace of mind for buyers who invest in their products.

In summary, the Slant/Fin S-60 to S-150 series stands out due to its robust construction, high efficiency, and user-friendly features. These models are designed to meet diverse heating needs while ensuring durability and long-term performance. Whether for residential or commercial use, consumers can trust Slant/Fin to deliver superior heating solutions.