RATINGS CHART – OIL BOILERS

®

INTREPID TR SERIES - WATER

 

 

I=B=R Burner

D.O.E.

I=B=R Burner

I=B=R Chimney Size

 

 

 

Dimensions (inches)

 

 

Tankless

 

 

 

 

 

 

 

Boiler

Heating

A.F.U.E.

 

 

 

 

Capacity

Capacity

Net Ratings

 

 

%

 

 

 

 

 

Boiler

Heater

Model

 

Oil Input

MBH

 

 

 

 

 

 

 

 

 

 

 

 

GPM**

 

 

 

 

 

 

 

 

 

 

 

Return

 

No.

 

 

 

 

 

 

 

 

Nom. Rect.

I.D.Round

 

 

Boiler

Front to

Flue

Overall

section

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Water

Steam

Steam

x Height§

x Height

 

 

Length

Flue ¢

Dia.

Circulator

Length

 

 

 

 

 

GPH

 

BTUH

Water

Steam

MBH

MBH

Sq. Ft.

(in x in x ft)

(in x ft)

Water

Steam

“A”

“B”

“C”

Flange

“E”

 

Water

Steam

 

 

 

“D”

 

TR-20

0.75

 

 

105,000

91

79

8 x 8 x 15

5 x 15

83.50

1112

8932

6Δ

114

2414

2

2.20

TR-30H

1.00

 

 

140,000

121

105

8 x 8 x 15

6 x 15

86.00

1478

10132

6

114

2758

3

3.00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TR-30

1.10

 

 

154,000

134

134

117

101

421

8 x 8 x 15

6 x 15

84.85

84.15

1478

10132

6

114

2758

3

3.20

3.00

 

 

1.25

 

 

175,000

151

131

8 x 8 x 15

6 x 15

83.50

1478

10132

6

114

2758

3

3.40

TR-40H

1.50

 

 

210,000

182

179

158

134

558

8 x 8 x 15

6 x 15

86.00

84.00

1814

112332

7

114

31

4

3.80

3.40

TR-40

1.60

 

 

224,000

195

195

170

146

608

8 x 8 x 15

7 x 15

84.45

83.80

1814

112332

7

114

31

4

3.90

3.50

 

 

1.80

 

 

252,000

218

190

8 x 8 x 15

7 x 15

83.33

1814

112332

7

114

31

4

4.15

TR-50H

2.00

 

 

280,000

243

239

211

179

746

8 x 8 x 15

7 x 15

86.00

84.00

2158

131332

8

112

3438

5

4.40

3.90

TR-50

2.10

 

 

294,000

256

255

223

191

796

8 x 8 x 15

8 x 15

84.06

83.45

2158

131332

8

112

3438

5

4.40

4.00

 

 

2.35

 

 

329,000

272#

237

8 x 12 x 15

8 x 15

2158

131332

8

112

3438

5

4.70

TR-60

2.60

 

 

364,000

298#

298#

259

224

933

8 x 12 x 15

10 x 15

25

15332

8

112

3734

6

4.90

4.50

 

 

2.85

 

 

399,000

327#

284

8 x 12 x 15

10 x 15

25

15332

8

112

3734

6

5.20

TR-70

3.10

 

 

434,000

352#

354#

306

266

1108

8 x 12 x 15

10 x 15

2838

162532

9

4118

7

5.45

5.00

 

 

3.35

 

 

469,000

381#

331

8 x 12 x 15

10 x 15

2838

162532

9

4118

7

5.70

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*Add Suffix: (P)Packaged water boiler less tankless heater, (PT)Packaged water boiler with tankless heater, (PPT)Packaged water boiler with provision for tankless heater, (PZ)Packaged steam boiler less

tankless heater, (PZT)Packaged steam boiler with tankless heater.

Ratings apply to the use of light oil at 140,000 Btu per gallon, and a .02% draft (negative pressure) over the fire.

The net I=B=R output ratings shown are based on an allowance for piping and pickup of 1.15 (water) or 1.33 (steam). D.O.E. capacity gross output is divided by the allowance to obtain net rating. The manufacturer should be consulted before selecting a boiler for unusual piping and pickup requirements such as intermittent system operation, extensive piping, etc.

§Nominal clay tile liner dimensions.

** Tankless heater rating based on intermittent draw.

Water boiler models TR-30, TR-40, TR-50, TR-60 and TR-70 have two firing rates. The boiler is factory shipped at the lower firing rate. To obtain the higher firing rate, refer to the Intrepid boiler installation instructions for the appropriate field adjustments.

#I.B.R. gross output

ΔCollar is oblong, will fit 6" diameter nominal connector.

NOTE: All boilers under 300,000 Btuh input are tested and rated for capacity under the U.S. Department of Energy (D.O.E.) Test Procedures for Boilers.å

SLANT/FIN CORPORATION, Greenvale, NY 11548 • Phone: (516) 484-2600

FAX: (516) 484-5921In Canada: Slant/Fin LTD/LTEE, Mississauga, Ontario

www.slantfin.com

©Slant/Fin Corp. 2007

Page 1
Image 1
Slant/Fin dimensions Ratings Chart OIL Boilers, Intrepid TR Series Water, GPH Btuh, Mbh ‡

TR Series specifications

The Slant/Fin TR Series is a highly regarded line of residential and commercial heating equipment known for its efficiency, reliability, and advanced technology. Designed to provide optimal heating solutions, the TR Series is a go-to choice for homeowners and contractors alike.

One of the standout features of the Slant/Fin TR Series is its compact size. The units are designed to fit seamlessly into various spaces, making them perfect for installations in homes that have limited room for traditional boilers or heating systems. This compact design does not compromise on performance; in fact, the TR Series is engineered to deliver powerful output while conserving space.

Another key characteristic of the TR Series is its innovative thermal efficiency. These units are designed with a focus on energy-saving technologies, which allow them to operate at high efficiency levels. Many models in the TR Series feature advanced burner systems that enhance combustion efficiency while reducing emissions. This not only lowers utility costs for consumers but also supports broader sustainability efforts.

The TR Series also stands out for its versatility. It can be used in a variety of applications, including baseboard heating, radiant floor heating, and even in some forced-air configurations. This adaptability makes the TR Series suitable for diverse heating needs, whether in residential settings, commercial buildings, or industrial applications.

Installation and maintenance are further simplified with the TR Series. The units come with comprehensive installation kits and user-friendly manuals, making it easier for professionals to set them up. Additionally, regular maintenance is straightforward due to easily accessible components, allowing for quick servicing when needed.

Durability is another hallmark of the Slant/Fin TR Series. Constructed with high-quality materials and robust engineering, these heating systems are designed to withstand the test of time. Users can expect long-term performance with minimal risk of breakdowns.

In summary, the Slant/Fin TR Series offers a blend of compact design, energy efficiency, flexibility, ease of installation, and durability. These qualities make it an appealing option for anyone in need of reliable heating solutions, ensuring comfort and satisfaction in homes and businesses alike. Whether you are upgrading an existing system or installing a new one, the TR Series is a dependable choice that stands as a testament to Slant/Fin’s commitment to quality and innovation in the heating industry.