Instructions for the installer
3.2Burner and nozzle characteristics table
| Rated |
|
|
|
|
|
Burner | heating |
| LPG – G30/G31 28/37 mbar |
| ||
| capacity |
|
|
|
|
|
| (kW) |
|
|
|
|
|
|
| Nozzle | Reduced | Flowrate | Flowrate | |
|
| diameter | mm | flowrate | g/h G30 | g/h G31 |
|
| 1/100 mm | 1/100 | (W) |
|
|
Auxiliary | 1.05 | 50 | 30 | 360 | 76 | 75 |
Semi rapid | 1.8 | 65 | 33 | 450 | 131 | 129 |
Rapid | 3 | 85 | 45 | 800 | 218 | 215 |
Ultrarapid | 3.3 | 91 | 65 | 1600 | 240 | 236 |
Burner
Auxiliary
Semi rapid
Rapid
Ultrarapid
| Rated |
|
|
|
|
|
| heating |
| Natural gas – G20 20 mbar |
| ||
| capacity |
|
|
|
|
|
| (kW) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Nozzle diameter |
| Reduced flowrate |
|
|
|
| 1/100 mm |
| (W) |
|
|
|
|
|
| ||
| 1.05 |
| 72 |
| 360 |
|
|
|
|
|
| ||
| 1.8 |
| 97 |
| 450 |
|
|
|
|
|
| ||
| 3 |
| 115 |
| 800 |
|
|
|
|
|
| ||
| 3.5 |
| 133 |
| 1600 |
|
3.3Arrangement of burners on cooking hob
BURNERS
1 | Auxiliary |
2 | Semi rapid |
3 | Rapid |
4 | Ultrarapid |
24