14.2 Burner and nozzle characteristics table

 

Rated heating

 

 

 

 

 

 

Burner

capacity

 

LPG – G30/G31 28/37 mbar

 

 

 

(kW)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Nozzle

By-pass

Reduced

Flowrate

Flowrate

 

 

 

diameter

1/100

flowrate

g/h G30

g/h G31

 

 

 

1/100 mm

mm

(W)

 

 

 

 

 

 

 

 

 

 

 

Auxiliary

1.0

50

30

350

72

71

 

Semi rapid

1.75

65

33

450

127

125

 

Rapid

2.5

79

45

800

181

178

 

Triple crown

3.5

94

65

1500

254

250

 

 

Rated heating

 

 

 

 

 

 

Burner

capacity

 

NATURAL GAS – G20 20 mbar

 

 

 

(kW)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Nozzle diameter

 

Reduced flowrate

 

 

 

 

1/100 mm

 

(W)

 

 

 

 

 

 

 

 

 

 

Auxiliary

1.0

 

72

 

350

 

 

Semi rapid

1.75

 

97

 

450

 

 

Rapid

2.5

 

108

 

800

 

 

Triple crown

3.5

 

133

 

1500

 

 

 

 

 

 

 

 

 

 

14.3 Arrangement of the burners on the hob

BURNERS

1 Auxiliary

2 Semi rapid

3 Rapid

4 Triple crown