Instructions for the installer

2. INSTALLATION OF THE OVEN

The oven must be set up on a perfectly flat surface and left standing free. Make sure to allow enough room at the back for easy access to the terminal strip for connection of the power cable to mains.

Installation must be carried out by a qualified technician in compliance with applicable regulations in force.

2.1 Electrical connection

Make sure that the power line voltage matches the specifications indicated on the rating plate located to the rear of the oven. This rating plate must never be removed.

The oven is equipped with a power converter which is designed to adapt power input to local current rating.

The converter is factory-set at 5450W. If required, this value may be reduced by adjusting the switch at the rear of the oven by means of a screwdriver.

MIN = Minimum power (3650W).

MED = Medium power (4550W).

MAX = Maximum power (5450W).

The oven is supplied complete with a H07RN-F three-core supply cable for operation from a 230Vpower supply.

For operation from a 400V3Npower supply, the original cable must be replaced and the terminal board connections modified accordingly. For access to the terminal board, remove the door located at the back of the oven.