Smeg FR132A For Great Britain only, WARNING - THIS APPLIANCE MUST BE EARTHED Fuse replacement

Models: FR132A

1 9
Download 9 pages 13.39 Kb
Page 9
Image 9
For Great Britain only:

INSTALLATION

For Great Britain only:

ELECTRICAL INFORMATION

WARNING - THIS APPLIANCE MUST BE EARTHED

Fuse replacement

If the mains lead of this appliance is fitted with a BS 1363A 13 amp fused plug, to change a fuse in this type of plug use an A. S. T. A approved fuse to BS 1362 type and proceed as follows:

1.Remove the fuse cover (A) and fuse (B)

2.Fit replacement 13A fuse into fuse cover

3.Refit both into plug.

2.The BLUE wire must be connected to the termi- nal which is marked with the letter "N" or colou- red black.

3.The BROWN wire must be connected to the ter- minal which is marked with the letter "L" or co- loured red.

BROWN

YELLOW & GREEN

BLUE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Connection to a

 

 

 

CABLE CLAMP

typical 13 amp plug

 

 

 

 

 

 

 

 

 

 

 

 

 

IMPORTANT: The fuse cover must be refitted when chang-ing a fuse and if the fuse cover is lost the plug must not be used until a correct replace- ment is fitted. Correct replacements are identified by the colour insert or the colour embossed in words on the base of the plug. Replacement fuse covers are available from your local electrical store.

CONNECTION TO A REWIREABLE PLUG

If the fitted plug is not suitable for your socket ou- tlet, then it should be cut off and disposed of in or- der to avoid a possible shock hazard should it be in- serted into a 13A socket elsewhere. A suitable alter- native plug should then be fitted to the cable.

The wires in this mains lead are coloured in accor- dance with the following code:

BLUE "NEUTRAL" ("N") BROWN "LIVE" ("L")

GREEN AND YELLOW "EARTH" ("E)

1.The GREEN AND YELLOW wire must be connec-

ted to the terminal in the plug which is marked with

the letter "E" or by the Earth symbol WARNING - THIS APPLIANCE MUST BE EARTHED or colou- red green or green and yellow.

For the Republic of Ireland only

The information given in respect of Great Britain will frequently apply, but a third type of plug and socket is also used, the 2-pin, side earth type. In this case, the wire which is coloured GREEN AND YELLOW must be connected to the EARTH con- tact, and the other two wires to the pins, irrespective of colour. The supply to the socket must be fitted with a 16 amp fuse.

14

Page 9
Image 9
Smeg FR132A manual For Great Britain only, WARNING - THIS APPLIANCE MUST BE EARTHED Fuse replacement