EN
Electronic control system instructions for use:
Technical Features:
•Power supply from mains: 230 VAC – 50/60 Hz
•Power consumption in standby: 20 mA
•Max. load applicable to LIGHTS connection: 150 W
•Max. load applicable to MOTOR connection: 400 W (capacitor motors only)
•
•Loads managed by
•Hardware and software EMC filtering.
•Connection to electronic control board by flat cable (10 poles) protected by flexible sheath (outside diameter 8 mm). Low voltage circuits (5 V).
•Possibility of operating an optional load at mains voltage.
•
•Optional analog/digital input for sensor and/or external control.
•
•
•Automatic sensing of mains frequency:
number 50 flashing on display = 230 VAC – 50 Hz mains, number 60 flashing on display = 230 VAC – 60 Hz mains,
•
•Software
•FILTER saturation alarm and alarm reset control (hour TIMER
for hood work).