| Mounting the hood body |
|
• | Before attaching the hood body, tighten the two screws Vr lo- | Vr |
| cated on the hood body mounting points. | |
|
| |
• Hook the hood body onto the screws 12a. |
| |
• Fully tighten the support screws 12a. |
| |
• | Adjust the screws Vr to level the hood body. | 12a |
Connections
DUCTED VERSION AIR EXHAUST SYSTEM |
|
|
When installing the ducted version, connect the hood to the |
|
|
chimney using either a flexible or rigid pipe ø 150 or 120mm, the |
|
|
choice of which is left to the installer. | ø 150 | ø 120 |
To install a ø 150 pipe | 10 | 9 |
| ||
• To install the dumper 10 |
| 10 |
• Fix the pipe in position using sufficient pipe clamps (not sup- |
|
|
plied). |
|
|
To install a ø 120 pipe
•To install a ø 120 mm air exhaust connection, insert the redu- cer flange 9 on the dumper 10.
•Fix the pipe in position using sufficient pipe clamps (not sup- plied).
•Remove any activated charcoal filters.
| RECIRCULATION VERSION AIR OUTLET |
|
| |
• | Push fit connection 15 onto the hood body outlet. | 15 | 14.1 | |
• | Insert the connection extension pieces laterally 14.1 in connec- | |||
|
|
tion 15.
• Make sure that the outlet of the extension pieces 14.1 is hori- zontally and vertically aligned with the chimney outlets. If this is not the case, adjust the position by either reversing the con- nection extension pieces 14.1 and then reassemble as described previously.
• Ensure that the activated charcoal filters have been inserted.