Connections

Connections

DUCTED VERSION AIR EXHAUST SYSTEM

When installing the ducted version, connect the hood to the chimney using either a flexible or rigid pipe ø 150 or 120 mm, the choice of which is left to the installer.

To install a ø 120 mm air exhaust connection, insert the reducer flange 9 on the hood body outlet.

Fix the pipe in position using sufficient pipe clamps (not supplied).

Remove possible charcoal filters.

RECIRCULATION VERSION AIR OUTLET

Connect the flange to the outlet on the shelf over the hood using a flexible or rigid pipe (ø120 or 150 mm).

To install a ø 120 mm air exhaust connection, insert the reducer flange 9 on the hood body outlet.

Fix the pipe in position using sufficient pipe clamps (not supplied).

Ensure that the activated charcoal filters have been inserted.

ø 150

ø 120

 

9

ELECTRICAL CONNECTION

Connect the hood to the mains through a two-pole switch having a contact gap of at least 3 mm..