3.2Burner and nozzle characteristics table
Burner
Auxiliary (1)
Semi rapid (2)
Rapid (3)
Ultra rapid (4)
Rated
heating
capacity
(kW)
1.05
1.75
2.3
4.0
LPG – G30/G31 30/37 mbar
Nozzle |
|
|
| Reduced |
| Flow rate |
| Flow rate | |||
diameter |
|
| mm |
|
| flow rate |
| g/h G30 |
| g/h G31 | |
1/100 mm |
|
| 1/100 |
|
| (W) |
|
|
|
| |
|
|
|
|
|
|
|
| ||||
50 |
| 30 (*) |
| 28/30 (**) |
|
| 400 |
| 76 |
| 75 |
|
|
|
|
|
|
| |||||
65 |
| 33 (*) |
| 32/33 (**) |
|
| 500 |
| 130 |
| 128 |
|
|
|
|
|
|
| |||||
75 |
| 45 (*) |
| 42/45 (**) |
|
| 800 |
| 166 |
| 164 |
|
|
|
|
|
|
| |||||
100 |
| 63 (*) |
| 63/65 (**) |
|
| 1600 |
| 291 |
| 286 |
*/**: diameters marked * and ** must be fitted respectively on valves marked * and **shown in point “4.1 Regulation of minimum for natural gas”.
Burner
Rated
heating
capacity
(kW)
Natural gas – G20 20 mbar
Auxiliary (1)
Semi rapid (2)
Rapid (3)
Ultra rapid (4)
1.05
1.75
2.3
4.0
Nozzle diameter
1/100 mm
72
97
103
135
Reduced flow rate
(W)
400
500
800
1600
3.3Arrangement of burners on cooking hob
BURNERS
1 Auxiliary
2 Semi rapid
3 Rapid
4 Ultra rapid