Instructions for the Installer
US INSTALLATION ONLY – 3 WIRE BRANCH CIRCUIT
Refer to figure 1, where local codes allow the connection of the ground wire from the applliance to the branch circuit neutral wire (white wire):
- The ground wire must be connected first;
- If local codes permit, connect the green or
- Connect the red and black leads from the oven to the corresponding leads in the junction box.
fig.1)
US INSTALLATION AND CANADIAN INSTALLATION – 4 WIRE BRANCH CIRCUIT
Refer to figure 2,
- Disconnect the green or
-The ground wire must be connected first;
-Connect the green or
from the appliance to the ground in the junction box (green colored wire). Do not connect the grounding wire to the neutral wire in the junction box.
- Connect the red and black leads from the |
|
|
|
|
|
|
|
| |
appliance to the corresponding leads in the |
|
|
| fig.2) |
junction box. |
|
|
| |
|
|
|
|
-Connect the white wire from the appliance to the neutral (white) wire in the junction box.
Connect to a 20A fuse or circuit breaker. Connect to copper wire only, or, if connecting to aluminum house wire, use
8