SERVICING

Always disconnect the appliance from the electricity main before proceeding with any servicing operation.

8) REPLACING THE ELECTRICAL COMPONENTS

For access to the various parts, remove the hotplate from the top of the cabinet. Then overturn it, unscrew screw “Z” and remove under part. (see fig. 9).

After these actions is possible to work on the plates, commutators, clamps and input cable.

N.B. In case of substitution of the input cable, the installer must keep the “earth” conductor longer than “live” ones, and must respect the cautions in paragraph “Electrical connection”.

To reassemble the appliance repeat the inverse process.

9)TECHNICAL CHARACTERISTICS OF THE ELECTRICAL COMPONENTS

To facilitate the job of the installer we present a scheme with the characteristics of the components.

POWER OF ELECTRICAL COMPONENTS DENOMINATIONS W

Denominations

W

 

 

Normal plate Ø 145 mm

1000

Normal plate Ø 180 mm

1500

 

 

TYPE AND SECTION OF THE POWER CABLES

Cable type

Single phase

 

Three phase

Three phase

power

 

 

power

power

 

 

 

 

110 V~

 

 

220 V 3N ~

220 V 2N~

 

 

 

 

 

 

Rubber

3 X 4.5 mm2

(*)

 

 

 

H05 RR-F

 

 

 

 

 

 

5 X 2.5 mm2 (*)

4 X 2.5 mm2 (*)

 

 

 

 

Polycroropene

3 X 4.5 mm2

(*)

 

 

 

 

H05 RN-F

 

 

 

 

 

(*) keeping in mind the contemporaneousness factor

 

 

9

Page 9
Image 9
Smeg SE435XT manual Servicing, Replacing the Electrical Components, Power of Electrical Components Denominations W