5.2Adjusting for bottled gas

Instructions for the Installer

5.2Adjusting for bottled gas

Undo the screw A and push the support B fully down. Remove the nozzle C with a spanner and fit the suitable one following the instructions in the tables referring to the type of gas to be used. The nozzle must not be tightened with a torque of more than 3 Nm. Return the support B to its original position, so that the nozzle C is perfectly covered.

Regulate the air flow by moving the Venturi pipe D until the distance “X” stated in point "5.5 Adjusting the primary air flow” is obtained and secure it with the screw A. When the adjustments are complete, restore the seals with wax or an equivalent material.

Nominal

BurnerheatBottled gas – G30/G31 30/37 mbar capacity

(kW)

Auxiliary

Semi rapid

Rapid (3)

Rapid (7)

Rapid (6)

Ultra-Rapid

Double Internal Crown (4)

External

Double Internal Crown (8)

External

1.05

1.7

3.5

2.9

3.1

4.2

0.9

3.3

0.9

4.0

Nozzle

By-pass

Reduce

Capacity

Capacity

diameter

mm

d heat

g/h G30

g/h G31

1/100 mm

1/100

capacity

 

 

 

 

(W)

 

 

48

30

400

76

75

62

33

500

124

121

89

50

1050

254

250

80

50

1050

211

207

85

50

1050

225

221

98

65

1600

305

300

45

30

400

62

61

87

55

1200

240

236

45

30

400

62

61

95

55

1200

291

286

5.3Adjusting for natural gas

The appliance is tested with G20 (2H) natural gas at the pressure of 20 mbar. To return the appliance to the condition required to use this type of gas, proceed as described in point “5.2 Adjusting for bottled gas” but select the nozzles and adjust the primary air flow for natural gas, as indicated in the table below and in point “5.5 Adjusting the primary air flow”.

 

 

 

 

 

Nominal

 

 

 

 

 

 

 

Burner

 

 

 

heat

 

Natural gas – G20 20 mbar

 

 

 

 

 

 

capacity

 

 

 

 

 

 

 

 

 

 

 

(kW)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Nozzle diameter

 

 

Reduced heat capacity

 

 

 

 

 

 

 

 

1/100 mm

 

 

(W)

 

 

 

 

 

 

 

 

 

 

 

 

 

Auxiliary

 

 

 

1.05

 

132

 

 

400

 

 

 

 

 

 

 

 

 

 

 

 

Semi rapid

 

 

 

1.7

 

165

 

 

500

 

 

 

 

 

 

 

 

 

 

 

Rapid (3)

 

 

 

3.5

 

250

 

 

900

 

 

 

 

 

 

 

 

 

 

 

Rapid (7)

 

 

 

2.9

 

230

 

 

1.05

 

 

 

 

 

 

 

 

 

 

 

Rapid (6)

 

 

 

3.1

 

240

 

 

900

 

 

 

 

 

 

 

 

 

 

 

Ultra-Rapid

 

 

 

4.2

 

300

 

 

1100

 

 

 

 

 

 

 

 

 

 

 

 

Double

 

Internal

 

0.9

 

126

 

 

400

 

 

Crown (4)

 

 

 

 

 

 

 

 

 

External

 

3.3

 

250

 

 

1200

 

 

 

 

 

 

 

 

 

 

 

Double

 

Internal

 

0.9

 

126

 

 

400

 

 

Crown (8)

 

 

 

 

 

 

 

 

 

External

 

4.0

 

140

 

 

1200

 

 

 

 

 

27