USB 2.0
Datasheet
8.3.9SMBus Alert Response Address
The SMBALERT# signal is not supported by the hub.
8.3.9.1Undefined Registers
The registers shown in Table 8.2 are the defined registers in the hub. Reads to undefined registers return 00h. Writes to undefined registers have no effect and do not return an error.
8.3.9.2Reserved Registers
Reserved registers should be written to ‘0’ unless otherwise specified. Contents read should be ignored.
8.4Default Configuration Option:
To configure the SMSC hub in its default configuration, strap CFG_SEL[2:0] to 00h. This procedure configures the hub to the internal defaults and enables the strapping options. Please see Section 8.2.1, "Internal Register Set (Common to EEPROM and SMBus)" for the list of the default values. For specific pin strapping options, please see Chapter 5, Pin Descriptions for instructions on how to modify the default values. Options include port disable and
8.5Default Strapping Options:
The USB251x can be configured via a combination of internal default values and pin strap options. Please see Table 8.2 for specific details on how to enable the
The strapping option pins only cover a limited
8.6Reset
There are two different resets that the hub experiences. One is a hardware reset via the RESET_N pin and the second is a USB Bus Reset.
8.6.1External Hardware RESET_N
A valid hardware reset is defined as assertion of RESET_N for a minimum of 1 μs after all power supplies are within operating range. While reset is asserted, the hub (and its associated external circuitry) consumes less than 500 μA of current from the upstream USB power source.
Assertion of RESET_N (external pin) causes the following:
1.All downstream ports are disabled, and PRTPWR power to downstream devices is removed (unless BC_EN is enabled).
2.The PHYs are disabled, and the differential pairs will be in a
3.All transactions immediately terminate; no states are saved.
4.All internal registers return to the default state (in most cases, 00(h)).
5.The external crystal oscillator is halted.
6.The PLL is halted.
The hub is “operational” 500 μs after RESET_N is negated. Once operational, the hub immediately reads
SMSC USB251x | 55 | Revision 1.0 |
DATASHEET