Chapter 11 DC Parameters
11.1Maximum Guaranteed Ratings
Operating Temperature Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0oC to +70oC Storage Temperature Range. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
*Stresses above the specified parameters could cause permanent damage to the device. This is a stress rating only and functional operation of the device at any other condition above those indicated in the operation sections of this specification is not implied.
Note: When powering this device from laboratory or system power supplies, it is important that the Absolute Maximum Ratings not be exceeded or device failure can result. Some power supplies exhibit voltage spikes on their outputs when the AC power is switched on or off. In addition, voltage transients on the AC power line may appear on the DC output. When this possibility exists, it is suggested that a clamp circuit be used.
11.1.1DC Electrical Characteristics
(TA = 0°C - 70°C, VDD33, VDDA33, = +3.3 V tolerance
Table 11.1 DC Electrical Characteristics
PARAMETER | SYMBOL | MIN | TYP | MAX | UNITS | COMMENTS |
|
|
|
|
|
|
|
I, IS Type Input Buffer |
|
|
|
|
|
|
Low Input Level | VILI |
|
| 0.8 | V | TTL Levels |
High Input Level | VIHI | 2.0 |
|
| V |
|
Input Leakage | IIL |
| +10 | uA | VIN = 0 to VDD33 | |
Hysteresis (‘IS’ Only) | VHYSI | 250 | 300 | 350 | mV |
|
Input Buffer with |
|
|
|
|
|
|
(IPU) |
|
|
|
|
|
|
Low Input Level | VILI |
|
| 0.8 | V | TTL Levels |
High Input Level | VIHI | 2.0 |
|
| V |
|
Low Input Leakage | IILL |
|
| 10 | uA | VIN = 0 |
High Input Leakage | IIHL |
|
| 30 | uA | VIN = VDD33 |
SMSC USB2524 | 53 | Revision 1.91 |
| DATASHEET |
|