LUBRICATION CHECK / LUBRICATE FREE-HAND LINKAGE

LUBRICATION CHECK / LUBRICATE FREE-HAND LINKAGE

Check the function of the Free-Hand controls: the con- trols should function as described in the CONTROLS section. It is critical for the safe operation of the unit that the controls disengage when released.

If the controls do not function properly, lubricate them. If lubrication does not rectify the problem, see your dealer. Under no circumstances should the unit be used if the controls are not functioning properly.

IMPORTANT NOTE

Storage

Figure 17. Lubricate Free Hand Control

It is very important that grease fittings on the auger shaft are lubricated regularly. If auger rusts to shaft, damage to worm gear may occur if shear pins do not break.

LUBRICATING THE AUGER SHAFT & ASSEMBLY

1.Remove cotter pin (C, Figure 18) and shear pin (B).

2.Use a grease gun and squirt several shots of grease into grease fitting (A).

3.Rotate auger assembly (D) several times to distribute the grease evenly. Repeat step 2.

4.Reinstall shear pin (B) and cotter pin (C).

5.Repeat procedure for other side.

STORAGE

Storage WARNING

Never store the unit (with fuel) in an enclosed, poorly ventilated structure. Fuel vapors can travel to an ignition source (such as a furnace, water heater, etc.) and cause an explosion.

Fuel vapor is also toxic to humans and animals.

C

B

A

B

C

A

D

D

Figure 18. Checking Auger Gear Case Lubrication

A.

Grease Fittings

C. Cotter Pins

B.

Shear Pins

D. Auger Assembly

Before you store your unit for the off-season, read the Maintenance and Storage instructions in the Safety Rules section, then perform the following steps:

Disengage the PTO, set the parking brake, and remove the key.

Perform engine maintenance and storage measures listed in the engine owner’s manual. This includes draining the fuel system, or adding stabilizer to the fuel (do not store a fueled unit in an enclosed struc- ture - see warning).

Before starting the unit after it has been stored:

Check all fluid levels. Check all maintenance items.

Perform all recommended checks and procedures found in the engine owner’s manual.

Allow the engine to warm up for several minutes before use.