Soleus Air FE1-05, 90CFM, FE1-07. FE1-09, 70CFM, FE1-11, 50 CFM, 110CFM manual Wiring Refer To Figure

Models: 110CFM 50 CFM FE1-05 FE1-11 70CFM FE1-07. FE1-09 90CFM

1 6
Download 6 pages 55.25 Kb
Page 4
Image 4
WIRING (REFER TO FIGURE 3)

1.Remove the louver (fan grate) from the unit before mounting.

2.Separate the air exhaust adaptor from the housing

3.Mount the air exhaust adapter to the wooden frame and secure using screws (as show in Figure 2).

4.Insert the housing to fit into the air exhaust adaptor and wooden frame. Secure the housing to the wooden frame using screws. To avoid vibration, place rubber washers between the housing and the wooden frame. Secure the housing to the air exhaust adaptor using the provided screws.

5.The flange of the housing must be leveled for the louver to fit properly.

6.Hang the unit to the roof using hangers when necessary.

7.Both installations seen in figure 2 can be used at the same time.

WIRING (REFER TO FIGURE 3)

IMPORTANT: The power must be disconnected before installation is complete.

IMPORTANT: Be certain all wiring complies with local safety codes and standards and that the unit is properly grounded.

1.Run the power leads from the wall switch, time switch, or speed control switch to the unit.

2.Using approved wire connectors, connect the supply wires to the fan wires: black (or brown) to black (or brown) and white (or blue) to white (or blue). Connect the ground wire (green or bare copper) to the ground connection on the fan junction box.