68 °F to 80 °F. And Air Conditioner mode when the room temperature is above 80 °F. Heating Mode when the room temperature is below 68 °F .

Sleep Mode (This mode can only be selected when using the Remote control )

1)To set Sleep mode, make sure the unit is in Air Conditioner mode or Heating mode.

2)Press the SLEEP Button on the remote control. The “ ” icon appears on the control panel display.

3)When in SLEEP mode, the fan will run on low to keep fan noise at a minimum.

4)When in Air Conditioner mode, the temperature setting will gradually increase to 2°F above the original set temperature for 6 hours. After 6 hours the temperature setting will return to the set temperature.

5)When in Heating mode, the temperature setting will gradually decrease to 2°F below the original set tem- perature for 6 hours. After 6 hours, the temperature setting will return to the set temperature.

6)When in Dehumidifier mode, the temperature will not change when Sleep mode is selected.

Compressor Indicator

 

 

 

The “

 

 

” icon will light up on the control panel display when the compressor turns on. The “

 

 

” icon

 

 

 

 

 

 

 

 

will turn off when the compressor shuts off.

 

 

 

Emergency Condensate Holding Tank

When the room temperature is low and the indoor humidity is high, the air conditioner may not be able to evaporate some of the moisture fast enough. When this happens, the water will accumulate in an emergency condensate tank inside the unit. Once the emergency condensate tank is full, the unit will automatically shut

off and the “ ” will appear on the control panel display. To empty the condensate tank, pull the drain plug at the bottom back of the unit. You will need a small pan, approximately 1” high to catch the water coming out of the condensate tank. Connect the supplied drainage hose to the back of the unit to aid in drainage into the pan. Once the condensate tank is drained, the unit will begin working within a few minutes. The emergency condensate tank is approximately 1.5 Liters of water. Another option is to purchase a small hose from a hard- ware store that can fit around the 5/8” drain plug on the back of the unit and drain the unit into a gravity drain or larger pan for continuous drainage. It is not advised to use continuous drainage when the room temperature

is higher than 90°F .

If you do not need the emergency tank emptied immediately simply leave the unit on. The fan in your air con- ditioner will continue to run to help evaporate the moisture as fast as possible. This will usually take around 60 minutes depending on how much water is in the tank.

12

Page 12
Image 12
Soleus Air PH5 manual Compressor Indicator

PH5 specifications

The Soleus Air PH5 is an innovative and energy-efficient portable air conditioner designed to provide optimal cooling and comfort in various settings. With its sleek design and compact size, it effortlessly fits into any room, making it an ideal choice for both home and office environments.

One of the key features of the Soleus Air PH5 is its powerful cooling capacity. Equipped with a high-efficiency compressor, it effectively delivers cool air quickly, ensuring that even large spaces can benefit from a comfortable atmosphere. The unit boasts multiple cooling modes, allowing users to customize their experience based on their preferences and the ambient conditions. The fan-only mode is particularly useful for circulating air without cooling, making it suitable for milder days.

The PH5 also incorporates cutting-edge technology for enhanced usability. Its advanced digital control panel allows for precise temperature settings and provides users with the ability to program the unit according to their schedule. The 24-hour programmable timer ensures that the air conditioner operates only when needed, thus conserving energy and reducing utility bills.

Another notable aspect of the Soleus Air PH5 is its impressive energy efficiency rating. By utilizing eco-friendly refrigerants and efficient components, this air conditioner minimizes its environmental impact while maximizing cooling performance. Additionally, it features an Energy Saver mode that further reduces energy consumption by automatically adjusting the cooling output based on the temperature.

User convenience is a priority in the design of the PH5. It comes with an easy-to-use remote control, enabling users to operate the unit from a distance. The unit is also designed with a washable filter, which helps maintain clean air quality while minimizing maintenance costs. The filter is easily accessible, making it simple for users to remove and wash as needed.

Moreover, the Soleus Air PH5 is engineered for quiet operation, making it suitable for use in bedrooms and other quiet spaces. The noise level is kept to a minimum, ensuring that users can enjoy a peaceful environment while staying cool.

In summary, the Soleus Air PH5 is a robust air conditioning solution that combines efficient cooling power with user-friendly features and environmentally conscious technologies. With its sleek design, advanced digital controls, and energy-saving capabilities, the PH5 stands out as a practical choice for cooling a variety of spaces. Whether for personal use or in a professional setting, this portable air conditioner delivers the comfort and performance users need.