REMOTE CONTROL OPERATING INSTRUCTIONS (Cont.)

REMOTE CONTROL OPERATING INSTRUCTIONS (Cont.)

5)Auto-on Timer: When the air conditioner is off, it can be set to automatically turn on in 30 minutes to 24 hours at the previous set mode and fan setting. To set the Auto-on Timer, press the TIMER button on the unit or remote control. Each touch of the +/- buttons on the remote will change the timer setting in 30 minute increments (.5 hours). The T-ONand H lights will blink while the Auto-on Timer is being set. Once the timer is set, press the TIMER button once more to save the setting. Press the ON/OFF button to cancel the timer.

Auto-off Timer: When the air conditioner is on, it can be set to automatically turn off in 30 minutes to 24 hours. To set the Auto-off Timer, press the TIMER button on the remote control. Each touch of the +/- buttons on the remote will change the timer setting in 30 minute (.5 hour) intervals. The T-OFFand H lights will blink while setting. To cancel the timer, press the ON/OFF button. Once the timer is set, press the TIMER button once more to save the setting. Press the ON/OFF button to cancel the timer.

6)Sleep Mode - Press the SLEEP mode button to engage SLEEP mode. Sleep mode automatically reduces the

set temperature by 2°F after one hour and 4°F after two hours. This feature limits compressor usage and enhances energy savings while you are sleeping.

7)Auto Mode - When AUTO mode is selected the air conditioner will automatically choose the operating mode base on the current room temperature. When the room is below 68°F the air conditioner will automatically fan the room to circulate air. When the room temperature is between 68°F-73°F the air conditioner will operate in Fan mode if it was previously selected or dehumidifier mode (if another mode was used previously) to remove humidity from the air as well as some cooling to help lower the room temperature. When the room temperature is between 74°F-79°F the air conditioner will always operate in dehumidifier mode. When the room temperature rises above 79°F, the unit will operate in air conditioner mode to maximize cooling. Auto mode uses pre-determined settings to keep you comfortable by choosing the most energy efficient mode based on the temperature of the room.