4Disconnect the USB cable.

For details, see page 80 or 86 of Operating Instructions supplied with the camera.

When using a computer with a

3Updating the version

1Press B/V on the control button to select [Version], then press B.

1

Setup 2

File Number:

USB Connect:

Video Out:

Clock Set:

“ERROR 10: Error” appears.

Cause: Version updating may have failed.

Remedy: Follow the steps in “Re-update procedure” and perform the update again.

Memory Stick slot

Memory Stick Duo Adaptor

2 Press v/V on the control button to select

[Update], then press z.

Update

Version: Cancel

7Update completion

1 Mount the just formatted “Memory Stick Duo” into a Memory Stick Duo Adaptor, then insert it into the Memory Stick slot.

• If you insert the “Memory Stick Duo” without first mounting it in a Memory Stick Duo Adaptor, you may be unable to remove the “Memory Stick Duo”.

2Copy the DSCT1V2.ash file in the CD-ROM to the “Memory Stick Duo”.

3Remove the “Memory Stick Duo”.

2Preparing the camera

1Insert the “Memory Stick Duo” into the camera.

2Connect the AC Adaptor (supplied) to the USB cradle (supplied) and a wall outlet (wall socket).

3 Connect the camera to the USB cradle.

Disconnect the USB cable if it is connected.

Use the AC Adaptor to prevent the power from cutting off partway through the

“Access” appears.

If the following errors occur at this time:

“ERROR 20: No software file” appears.

Cause: The file is not present in the “Memory Stick Duo”.

Remedy: Check the contents of the “Memory Stick Duo” with the computer, then perform the procedure again starting from “Software updating instruction”.

“ERROR 30: Format Memory Stick before use” appears.

Cause: There are multiple files and folders in the “Memory Stick Duo”.

Remedy: Format the “Memory Stick Duo” with the camera and perform the procedure again starting from “Preparing the update firmware”.

“ERROR 40: Invalid file” appears.

Cause:

The file in the “Memory Stick Duo” is not correct.

The firmware version is the same or older than the existing one.

The update target model is different.

Remedy: Check the current version, then return to the top page, select and download the correct firmware, and perform the procedure again starting from “Software updating instruction”.

The “Finished” screen appears. Turn off the camera.

Be sure to press the RESET button after turning off the power. (When you press the RESET button, the date/time and other settings are canceled.)

8 Checking the updated version

 

 

 

 

 

 

 

Setup 2

 

 

Press the POWER button while holding down

 

 

File Number:

 

 

 

 

USB Connect:

 

 

MENU, and turn on the camera.

 

 

Video Out:

 

 

 

1

 

 

 

Clock Set:

 

 

Check

 

(Setup 2) at the Setup screen to make sure

 

 

2004 1 1 10:30:00AM

 

 

 

 

2

 

 

 

Version:

2

 

that the version has been updated.

<

 

If the version has been updated to “2”, the procedure is

MENU SELECT

 

 

 

 

 

 

 

complete.

 

 

 

 

 

After finishing the update, format the “Memory Stick Duo” to delete the update file.

Re-update procedure

When updating fails, follow the procedure below and perform re-update.

1 Turn off the camera and check

that the “Memory Stick Duo” is

procedure.

The battery pack cannot be used for this procedure.

Software updating instruction

1Setting the update mode

1Set the mode switch to .

2 Press the POWER button while holding down MENU, and turn on

4Checking the version before updating

Check the current version and the updated version, then press v on the control button to select [OK], and press z.

The “Software Update” screen appears. Select [Cancel] to return to the Setup screen.

Software Update Current Version: 1

New Version : 2

OK

Cancel

inserted into the camera.

• You cannot use a “Memory Stick PRO

Duo” for this re-update procedure.

2Wait for 5 seconds or more, then

turn on the camera.

Re-update starts, and the access lamp on the camera lights up.

After about one minute, the access

lamp turns off and the update is complete.

Access lamp

the camera.

Mode switch

m

POWER

MENU

 

2Checking the update mode

1Press MENU.

The menu appears.

2 Press B on the control button to select in the menu, then press

Bagain.

The Setup screen appears.

 

 

 

 

 

3 Press V on the control button to select

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

Setup 2

 

 

(Setup 2).

 

 

File Number:

 

 

“Version: 1” appears.

 

 

USB Connect:

 

 

 

 

Video Out:

 

 

 

 

 

 

When “Version: 1” does not appear, turn off the camera, then

 

1

Clock Set:

 

 

perform the procedure again starting from “Setting the

 

 

2004 1 1 10:30:00AM

 

<

Version:

1

 

update mode”.

 

MENU SELECT

 

 

When “Version: 2” appears, the camera has already been updated and there is no need to update the version.

5Update the program

Press v on the control button to select [OK], then press z.

Updating starts.

6Updating

The “Updating” screen appears and the a indicators flash.

When all three indicators change from flashing to lit, the updating is complete.

Updating takes a number of minutes (normally about 1 minute).

 

Flashing

Updating

Start

Don’t turn off

 

 

1/3 complete

If not blink the circles more than 30sec,

2/3 complete

see the “Software updating instruction”

If the following errors occur at this time:

aaado not flash for 30 seconds or more at the “Updating” screen.

Cause: Version updating may have failed.

Remedy: Follow the steps in “Re-update procedure” and perform the update again.

When performing re-update, nothing appears on the LCD screen, but the update is being performed.

3Turn off the camera.

Be sure to press the RESET button after turning off the power. (When you press the RESET button, the date/time and other settings are canceled.)

4Follow the procedure in “Checking the updated version” and

check the firmware version.

Press the POWER button while holding down MENU, then check (Setup

2

2) at the Setup screen to make sure that the version has been updated. If the version has been updated to “2”, the procedure is complete.

If the following error occurs at this time:

The access lamp on the camera flashes or lights up during re- update, but does not turn off even after 3 minutes or more have passed.

Cause: Trouble occurred with the “Memory Stick Duo” during updating.

Remedy: Consult your nearby Sony service center or service facility.

Trademarks

Microsoft and Windows are either registered trademarks or trademarks of the U.S. Microsoft Corporation in the United States and/or other countries.

Macintosh and Mac OS are trademarks or registered trademarks of Apple Computer, Inc.

In addition, system and product names used in this manual are, in general, trademarks or registered trademarks of their respective developers or manufacturers.