Command List
VISCA Camera-Issued Messages
ACK/Completion Messages
| Command Messages | Comments |
|
|
|
ACK | z0 4y FF | Returned when the command is accepted. |
| (y:Socket No.) |
|
|
|
|
Completion | z0 5y FF | Returned when the command has been executed. |
| (y:Socket No.) |
|
|
|
|
z = Device address + 8 |
|
|
Error Messages
| Command Messages | Comments |
Syntax Error | z0 60 02 FF | Returned when the command format is different or when a command with illegal |
|
| command parameters is accepted. |
|
|
|
Command Buffer Full | z0 60 03 FF | Indicates that two sockets are already being used (executing two commands) and the |
|
| command could not be accepted when received. |
|
|
|
Command Canceled | z0 6y 04 FF | Returned when a command which is being executed in a socket specified by the |
| (y:Socket No.) | cancel command is canceled. The completion message for the command is not |
|
| returned. |
|
|
|
No Socket | z0 6y 05 FF | Returned when no command is executed in a socket specified by the cancel |
| ||
| (y:Socket No.) | command, or when an invalid socket number is specified. |
|
| |
|
|
|
Command Not Executable | z0 6y 41 FF | Returned when a command cannot be executed due to current conditions. For |
| ||
| (y:Socket No.) | example, when commands controlling the focus manually are received during auto |
|
| |
|
| focus. |
|
|
|
Network Change Message
| Command Message | Comments |
|
|
|
Network Change | z0 38 FF | Issued when power is being routed. |
|
|
|
43