Eclipse

When designing the housing, refer to the dimensional allowance as shown in the figure below.

Basic Functions

Spectral Sensitivity Characteristics

FCB-EX980S/EX980SP

10.68

13.13

˚

)

9

30

 

.

 

.

12

(

28

 

 

Eclipse of the Lens

The eclipse phenomenon occurs with the FCB-980/ 980P. This is because a sufficient amount of aperture is not available due to the CCD size and the lens structure of the FCB-980/980P. However, it has been verified that the eclipse will not be visible in the case of a more than 90 % effective image.

For your reference, see the following diagram.

B/20=5%

B/20=5%

 

 

 

 

 

 

A/20=5%

A

A/20=5%

B

: Normal scan display area : Under scan display area

FCB-EX980/EX980P

Vibration

Specifications

Test Method (Random vibration)

Fix the camera at the four fixation points of the base using M2 screws.

Perform the random vibration test under the following conditions in the X, Y and Z directions for 20 minutes in each direction.

The camera vibration specification is to have no malfunction after this test.

Power spectrum density

5 to 50 Hz

4.14 m2/s3

{0.043 G2/Hz}

 

50 to 100 Hz

–36 dB/oct

 

 

 

Effective overall value

14.3 m/s2

{1.46 G}

 

 

 

Test time

20 minutes

 

 

 

 

 

29