Grid

Use the grid displayed on the screen to set mask positions (see the figure below).

14hex (20(10))

14hex (20(10))

Basic Functions

Alarm Function

This function instructs the camera to detect movement within the monitoring area and then send an alarm signal automatically.

A High level signal is output when camera detects movement inside the monitoring area. A Low level signal is output when object stops moving.

However, when the mode is set to “DAY/NIGHT”, the High level signal is output for dark and the Low level signal is output for bright.

The Detect signal goes out through the serial command (VISCA) communication line.

Example

1.A door is motionless, so the Detect Level is Low.

2.At the moment when the door is opened by someone, the Detect Level goes to High.

3.The Detect Level is High while the shooting object is moving.

4.When the door is closed, Detect Level goes to Low again, or signals are output only once at the time of switching between High Level and Low Level.

18