7
FWD-50PX2
Code Table(1-a)
[a]Function [b]Range/Switch Code Command
Control Enquiry Standby Power On
0x35 PAP Input Detect*20x0A INPUT2 RGB No Yes Disable Enable
(Left/Main) 0x0B INPUT2 COMPONENT
0x0C OPTION1 VIDEO
0x0D OPTION1 S VIDEO
0x0E OPTION1 RGB
0x0F OPTION1 COMPONENT
0x10 OPTION2 VIDEO
0x11 OPTION2 S VIDEO
0x12 OPTION2 RGB
0x13 OPTION2 COMPONENT
0x20 INPUT1 DVI
0x36 PAP Input Detect*2 0x0A INPUT2 RGB No Yes Disable Enable
(Right/Sub)
0x0B INPUT2 COMPONENT
0x0C OPTION1 VIDEO
0x0D OPTION1 S VIDEO
0x0E OPTION1 RGB
0x0F OPTION1 COMPONENT
0x10 OPTION2 VIDEO
0x11 OPTION2 S VIDEO
0x12 OPTION2 RGB
0x13 OPTION2 COMPONENT
0x20 INPUT1 DVI
*1: Transmit the next command 10 seconds after Power On and Power Off commands are transmitted. If not, correct data may not be able to be acquired.
*2: The command of Option 2 slot is assigned to Option 1 slot because the BKM-FW32 is installed in Option 2 slot.
*3: The Picture Position arrangement is as shown below.
IP Address
Syntax Header Category Function Data1 Data2 Data3 Data4 Data5 Check Sum
Control 0x8C 0x00 0x42 0x05 Address Address 1 Address 2 Address 3 0xXX
00x00-0xFF 0x00-0xFF 0x00-0xFF 0x00-0xFF
Answer Header Answer Check Sum
Control 0x70 0x00 0x70 Completed
0x70 0x03 0x73 Command Canceled
IP Address ex)
192.128.14.1 192 (0xC0) Address 0
128 (0x80) Address 1
14 (0x0E) Address 2
1 (0x01) Address 3
* IP Address command can be carried out even in the standby state.
12
43