15
Installation
When attaching the V-wedge shoe, taking the total weight
of the adaptor, camera, studio lens and viewfinder, and the
size of the pan and tilt head of the tripod into consideratio n,
choose a position such that the unit will be mounted stably
on the tripod.
Some tripods cannot be attached unless the feet and cable
hanger are removed from the adaptor.
Remove the feet and hanger to use such a tripod.

Attaching the stopper [1500][1507]

For use of the HDVF-9900 viewfinder in combination,
attach the stopper supplied with the adaptor to the side
panel of the adaptor.
Mounting the Camera in the Adaptor
• Be sure to turn off the camera power before mounting.
• If the camera is mounted with the power ON, the
protection circuit of the adaptor will be activated. In such
a case, unmount the camera from the adaptor, turn off the
power, wait for more than 30 seconds, then mount it
again.
Mounting procedure
While the figures of the adaptors in the following steps
show the states where the studio lens and the large
viewfinder are not attached, the camera can also be
mounted after attaching the large lens and the large
viewfinder to the adaptor.
For the HDLA1507, start from step 2.
1
Check that the camera lock lever on the front panel is
in its upper position.
Note
Bottom of the adaptor
V-wedge shoe
Feet Feet
Cable hanger
Example: To remove the feet near the V-wedge shoe
Feet
Notes
Remove the blind
bush from the
screw hole on the
side panel.
Attach the stopper
using the supplied
screw.
[1500][1507]