151
Technical References

Phantom function (salvo function)

This function allows the switching of multiple crosspoints at the same time with a single button
operation. The following two types of settings can be made:
(1) “Local phantom”: Registers up to 64 crosspoints for each remote control panel.
(2) “Global phantom”: Registers up to 2,800 crosspoints for the routing switchers set by the
primary stations.
Names can be set for phantoms (groups of crosspoints switched simultaneously). Since
local phantoms are registered for each remote control panel, the same name can be used
for a different group of crosspoints on each remote control panel.
On the other hand, global phantoms are useful when there are many crosspoints to switch
simultaneously, or when sharing the same phantom across multiple remote control panels.
Also, the number of phantoms set for each unit can be increased by combining global
phantoms and local phantoms.
SET INHIBIT TABLE
DEST. SOURCE
001 01--08 09--16 17--24 25--32 33--40 41--48 49--56 57--64
OUT001 xxxxxxxx xxxxxxxx xxxxxxxx xxxxxxxx -------- -------- -------- --------
OUT002 -------- -------- -------- -------- xxxxxxxx xxxxxxxx xxxxxxxx xxxxxxxx
OUT003 xxxxxxxx xxxxxxxx xxxxxxxx xxxxxxxx xxxxxxxx xxxxxxxx xxxxxxxx xxxxxxxx
OUT004 xxxxxxxx xxxxxxxx xxxxxxxx xxxxxxxx xxxxxxxx xxxxxxxx xxxxxxxx xxxxxxxx
OUT005 xxxxxxxx xxxxxxxx xxxxxxxx xxxxxxxx xxxxxxxx xxxxxxxx xxxxxxxx xxxxxxxx
OUT006 xxxxxxxx xxxxxxxx xxxxxxxx xxxxxxxx xxxxxxxx xxxxxxxx xxxxxxxx xxxxxxxx
OUT007 xxxxxxxx xxxxxxxx xxxxxxxx xxxxxxxx xxxxxxxx xxxxxxxx xxxxxxxx xxxxxxxx
OUT008 xxxxxxxx xxxxxxxx xxxxxxxx xxxxxxxx xxxxxxxx xxxxxxxx xxxxxxxx xxxxxxxx
DEST. SOURCE
009 01--08 09--16 17--24 25--32 33--40 41--48 49--56 57--64
OUT009 xxxxxxxx xxxxxxxx xxxxxxxx xxxxxxxx xxxxxxxx xxxxxxxx xxxxxxxx xxxxxxxx
OUT010 xxxxxxxx xxxxxxxx xxxxxxxx xxxxxxxx xxxxxxxx xxxxxxxx xxxxxxxx xxxxxxxx
OUT011 xxxxxxxx xxxxxxxx xxxxxxxx xxxxxxxx xxxxxxxx xxxxxxxx xxxxxxxx xxxxxxxx
OUT012 xxxxxxxx xxxxxxxx xxxxxxxx xxxxxxxx xxxxxxxx xxxxxxxx xxxxxxxx xxxxxxxx
OUT013 xxxxxxxx xxxxxxxx xxxxxxxx xxxxxxxx xxxxxxxx xxxxxxxx xxxxxxxx xxxxxxxx
OUT014 xxxxxxxx xxxxxxxx xxxxxxxx xxxxxxxx xxxxxxxx xxxxxxxx xxxxxxxx xxxxxxxx
OUT015 xxxxxxxx xxxxxxxx xxxxxxxx xxxxxxxx xxxxxxxx xxxxxxxx xxxxxxxx xxxxxxxx
OUT016 xxxxxxxx xxxxxxxx xxxxxxxx xxxxxxxx xxxxxxxx xxxxxxxx xxxxxxxx xxxxxxxx
HDS-X5800 V1.00
F1: SEARCH F2: JUMP F3: LEFT F4: RIGHT
STATION NUMBER 1
Ctrl-E: RETURN TO MENU
“-” mark is an inhibited crosspoint.
Figure-2 Crosspoint disabling function
Input/output system protection functions (protect and secret functions)
There are two protection functions:
“Protect” function prevents the output destination from being re-assigned from another remote
control panel.
“Secret” function ‘hides’ the input sources that cannot be selected to any destination from any
remote control panel.

Crosspoint disabling function

This function inhibits individual crosspoints to limit the availability of each source to individual
destinations.