Front Optic Installation / Removal

To Remove Optic

1.Slide LOCKING PIN away from optic.

2.Rotate optic counter clockwise.

3.Pull away from housing.

To Install Optic

1.Perform an o-ring inspection.

2.Align optic to housing details.

3.Press optic into housing.

4.Rotate clockwise until LOCKING PIN engages.

Monitor Back ID and Operation

Monitor Back installs into the Stingray in the same manner as the Rear Plate.

Monitor Back Identification

B Button

Video Out Bulkhead Port

LED Moisture Alarm

Monitor Back Operation

B - Adjusts the brightness of the Monitor Back LCD, adjustment will not affect the recorded image.

VIDEO OUT BULKHEAD PORT - Allows the addition of a video out cable for surface viewing while Stingray is underwater.

LCD MOISTURE ALARM - Audio and visual alarms will signal if moisture is detected inside the housing. Alarm performs a three second diagnostic check when initially receiving power.

When camcorder transitions from Memory to Camera modes

there is a 2-3 seconds pause while the camcorder keys the tape. Monitor Back will black out during this time and LED alarm will sound when Monitor Back is re-powered.

Pre-Dive Checklist

1)Install a Mini DV / Digital 8 tape and Memory Stick in the camcorder.

2)Install a completely charged battery in the camcorder.

3)Verify operation of all housing controls.

4)Check that the front bayonet port is securely engaged and that the latch pin is in the locked position. Clean lens if necessary.

5)Check that the rear plate o-rings are seated correctly and that the rear latches are in the closed and locked position.

First Time Use

All Light and Motion housings are pressure tested prior to

shipping. However, there could be unseen damage due to shipping. A test dive without the camcorder in the housing is recommended.

After the initial dive with just the housing, make the following checks.

1.Dry off housing exterior.

2.Remove the Rear Plate and visually inspect for moisture.

3.Reach inside the housing and trace a finger around all view ports and mating surfaces.

4.If any water is detected, contact the housing reseller or the Light & Motion service department.

After Diving Care

1.Immediately submerge the housing in fresh water. While in fresh water, work all the switches and press all the buttons, to work any remaining salt water out of the housing buttons.

2.Remove housing from rinse tank and then simply towel dry.

Housing Storage

Store housing and Travel Case in a dry location the first 24 hours after a dive. Leave the Rear Plate off the housing to allow for air circulation. Similarly, leave Travel Case Lid about two inches open. Allow any residual water to evaporate from the Travel Case prior to storing the housing.

Page 5
Image 5
Sony TRV530, TRV730 Front Optic Installation / Removal, Monitor Back ID and Operation, Pre-Dive Checklist, First Time Use