INSTALLATION MARATHONER GOLD & SILVERSTAR GAS CONVECTION OVENS
PAGE 22 OPERATORS MANUAL 1181887 REV 1
INSTALLATION

Step 8: Connect Gas Supply

NOTICE
The installation must conform with local codes, or in the absence of local codes, with the National
Fuel Gas Code, ANSI Z223.1, Natural Gas Installation Code, CAN/CGA-B1 49.1, or the Propane
Installation Code CAN/CGA-B149.2, as applicable, including:
1. The applia nce and its individual shutoff valve must be disconnected from the gas supply pi ping
system during any pressure testing of that system at test pressures in exc ess of 1/2 psi (3.45
kPa).
2. The appliance must be isolated from the gas supply piping system by clos ing its individual manual
shutoff valve during any pressure testing of the gas supply piping system at test pressures equal
to or less than 1/2 psi (3.45 kPa).
A 3/4" NPT line is provided at the rear for the gas connection.
If this equipment is being installed at over 2,000 feet altitude an d that information was not specified when
ordered, contact the appropriate authorized Southbend Service Represent ative or the Southbend Service
Department. Failure to install with proper orifice sizing will result in poor perfor mance and may void the
warranty.
The serial plate is located inside the front lower panel. It indic ates the type of gas the unit is equipped to
burn. All Southbend equipment is adjusted at the factory. Check t ype of gas on serial plate.
These models are design-certified for operation on natural or propane gas es. For natural gas, the regulator
is set to deliver a 4.5" W.C. pressure to the manifold. For propane gas , it is set to deliver 11" W.C.
This appliance should be connected ONLY to the type of gas f or which it is equipped. The inlet pressure
before the regulator should be 7-10" W.C. for natural gas or 11-14" W .C. for LP gas.
An adequate gas supply is imperative. Undersized or low pressure lines will restrict the volume of gas
required for satisfactory performance. Fluctuations of more than 25% on natural gas or 10% on propane
gas will create problems and affect burner operating characteristics.
An adequate gas supply line to the unit should be no smaller than t he I.D. of the pipe from the unit to which
it is connected.
Purge the supply line to clean out dust, dirt, or other foreign matter befor e connecting the line to the unit.
! CAUTION
ALL PIPE JOINTS AND CONNECTIONS MUST BE TESTED THOROUGHLY FOR GAS L EAKS.
USE ONLY SOAPY WATER FOR TESTING ON ALL GASES. NEVER USE AN OPEN FLAME TO
CHECK FOR GAS LEAKS. ALL CONNECTIONS MUST BE CHECKED FOR LEAK S AFTER THE
UNIT HAS BEEN PUT INTO OPERATION. TEST PRESSURE SHOULD NOT EX CEED 1/4" W.C.

Step 9: Check the Installation

1. Check that all screws and bolts are tightened.
2. Move the oven into the position at which it will be operated.
3. Check that the oven is level. If not, adjust the legs.
4. Check that the appropriate clearances are satisfied ( see page 8).