Spectra QM95 Specifications, General Care, Safety And Storage, Transport, Trouble Shooting

Models: QM95

1 2
Download 2 pages 32.5 Kb
Page 2
Image 2

General Operation

Addition and Subtraction

+ The next measure is added to the previous one

- The next measure is subtracted from the previous one

Clear button

Press the C button to clear the last reading. During area measures, the C button clears the most recent measure, but preserves previous measures.

– 13 –

Settings menu (to change sound and unit of measure)

1)With the tool switched off, press and hold the Power On/Off Button for approximately 2 seconds to enter menu mode.

MENU

m

2)

Press + to cycle sound on or off

 

 

3)

Press the – button to cycle through unit measure options:

 

 

 

 

 

 

 

m

cm

mm

 

 

 

in

1/8 in

1/16 in

1/32 in

 

 

ft

1/8 ft

1/16 ft

1/32 ft

 

 

yd

 

 

 

 

4) To close the menu, press and hold the Power On/Off Button for approximately 2 seconds. The tool is switched off and settings are saved.

– 14 –

Specifications

Measuring Range*

0.1 to 200 m (1 to 650 ft)

Accuracy

± 1.0 mm typical (± 1/24 in)

 

 

Functions

Individual measure, Continuous measure

 

Area, Addition, Subtraction

 

 

Measure reference

Front, Rear, Rear with Extension tab

Automatic shut off

Laser - 1 minutes / Product - 10 minutes

Battery life (alkaline)

8000 measures

 

Operating temperature

-15⁰C to +50⁰C

(3⁰F to 122⁰F)

Storage temperature

-25⁰C to +65⁰C

(-13⁰F to 149⁰F)

Power supply

2 x AA x 1.5V

 

Power indication

LCD 4 segments - 100%, 75% 50%, 25%

Laser Safety

Class II as per EN 60825-1:2007;

 

IEC 60825-1:2007 CFR 21 § 1040 (FDA)

Laser Type / Power

635 nm visible red / < 1.0 mW

Dimensions

62 x 28.5 x 120 mm (2.4" x 1.2" x 4.7")

Weight

217 g (7.7 oz) with batteries

Dust & Water resistance

IP54

 

Drop Performance

1.5 m (5 ft)

 

*Dependent upon several factors. See table next page

15 –

Measurement range:

Distance performance and measure speed is dependent upon several factors:

Ambient lighting

Target reflectivity

Dust and particles in the air

Temperature

Measurement

Albedo

Temp.

 

Light

Range

range on

>5

-10⁰C to +50⁰C

 

<1000 lx

0.17 to 200 m

standard

 

1

+10⁰C to +35⁰C

 

<1000 lx

0.17 to 120 m

target

 

 

0.2

+10⁰C to +35⁰C

 

<1000 lx

0.17 to 55 m

 

0.2

-10⁰C to +50⁰C

 

<1000 lx

0.17 to 50 m

 

1

+10⁰C to +35⁰C

 

100000 lx

0.17 to 50 m

 

0.2

+10⁰C to +35⁰C

 

100000 lx

0.17 to 50 m

 

1

-10⁰C to +50⁰C

 

100000 lx

0.17 to 45 m

 

0.2

-10⁰C to +50⁰C

 

100000 lx

0.17 to 45 m

 

Minimum measuring distance

 

170 mm

 

Clearness

 

 

 

>300 m

 

 

– 16 –

 

 

General Care, Safety And Storage

General safety rules

a)Check the condition of the tool before use.

b)The user must check the accuracy of the tool after it has been dropped or subjected to other mechanical stresses.

c)Although the tool is designed for the tough conditions of jobsite use, as with other measuring instruments it should be treated with care.

Do not use prisms or mirrored surfaces

Distances can be measured from all stationary targets without a highly reflective surface, i.e. concrete, stone, wood, plastic, paper, etc. The use of prisms or other highly reflective targets is not permissible and, if attempted, may falsify the results.

Calibration Check

It is recommended to occasionally check the calibration of the tool.

1)Select a known measure distance about 1 to 5 meters (3 to 15 ft) that does not change over time.

2.) Measure the distance 10 times. Calculate the mean deviation from the actual distance. The measured mean deviation should be less than the typical accuracy tolerance of ± 1.5 mm (± 1/16 in)

Cleaning and drying

1.Blow dust off the lens.

2.Do not touch the lens with the fingers.

3.Use only a clean, soft cloth for cleaning. If necessary, moisten the cloth slightly with pure alcohol or a little water.

NOTE Do not use any other liquids as these may damage the plastic components.

Storage

The temperature limits for storage of your equipment must be observed, especially in winter / summer.

Remove the tool from its pouch if it has become wet. The tool, its carrying case and accessories should be cleaned and dried (at maximum 40°C). Repack the equipment only once it is completely dry. Check the accuracy of the equipment before it is used after a long period of storage or transportation.

Transport

Use the original packaging or packaging of equivalent quality for transporting or shipping your equipment.

CAUTION

Always remove the batteries before shipping the tool.

Trouble Shooting

Fault

Possible cause

Remedy

 

 

 

The unit can’t be switched on.

The batteries are exhausted.

Replace the batteries.

 

Incorrect battery polarity.

Insert the batteries correctly and close the battery

 

 

compartment cover.

 

The button is faulty.

Contact Service

No distances displayed by the unit.

Measure Button was not pressed.

Press the Measure Button.

 

Unit was not switched on

Press the Measure Button.

 

Faulty display.

Contact Service

Frequent error messages or the unit doesn’t

The target surface is too brightly lit by the sun.

Measure from the other direction – sun from behind.

measure.

 

 

The target surface is too shiny.

Take measurements from less shiny surfaces.

 

 

The target surface is too dark.

Use a lighter colored surface

 

Bright sunlight towards the tool.

Shade the unit.

Temperature indicator - symbol in the display

Temperature too high (>+50 °C / 122 °F)

Allow the unit to cool down.

 

Temperature too low (<-10 °C / 14 °F)

Allow the unit to warm up.

Unfavorable signal conditions - symbol in the

Insufficient reflected laser light.

Observe the minimum measuring distance (>200

display

 

mm / 8 inch from the front edge of the unit);

 

 

clean the lenses; take the measurement from a

 

 

different surface or use a target plate.

General hardware fault - symbol in the display

Hardware fault

Switch the unit off and on again.

– 17 –

Laser Safety

Use of this product by people other than those trained on this product may result in exposure to hazardous laser light.

Do not remove warning labels from the unit.

The QM95 is a Class 2M (635 nm) laser product .

Never look into the laser beam or direct it to the eyes of other people.

Always operate the unit in a way that prevents the beam from getting into people‘s eyes.

– 18 –

Warranty

Trimble warrants the Quick Measure QM95 to be free of defects in material and workmanship for a period of 3 years. For the first 2 years, Trimble or its authorized Dealer or Service Center will repair or replace, at its option, any defective part, or the entire product, for which notice has been given during the warranty period. For the 3rd year, an exchange fee may apply. This warranty period is in effect from the date the system is delivered by Trimble or its authorized Dealer to the purchaser, or is put into service by a Dealer as a demonstrator or rental component.

Any evidence of negligent or abnormal use, or any attempt to repair equipment by other than factory-authorized personnel or Trimble certified or recommended parts, automatically voids the warranty.

The foregoing states the entire liability of Trimble regarding the purchase and use of its equipment. Trimble will not be held responsible for any consequential loss or damage of any kind.

This warranty is in lieu of all other warranties, except as set forth above, including an implied warranty. Merchantability of fitness for a particular purpose is hereby disclaimed.

Customers should send products to the nearest authorized Factory, Dealer or Service Center for warranty repairs, freight prepaid. In countries with Trimble Service Subsidiary Centers, the repaired products will be returned to the customer, freight prepaid.

– 19 –

Service Request

To locate your local dealer or authorized Trimble Service Center outside the U.S.A. for service, accessories, or spare parts, contact one of our offices listed below.

North-Latin America

Asia-Pacific

Trimble / Spectra Precision Division

Trimble Navigation Singapore PTE Ltd.

8261 State Route 235

80 Marine Parade Road, #22-06

Dayton, Ohio 45424-6383

Parkway Parade

U.S.A.

Singapore, 449269

(888) 527-3771

+65 6348 2212 Phone

(Toll Free in U.S.A.)

+65 6348 2232 Fax

+1-937-203-4419 Phone

China

+1-937-482-0030 Fax

Trimble Beijing

www.trimble.com/spectra

Room 2805-07, Tengda Plaza,

 

Europe

No. 168 Xiwai Street

Trimble Kaiserslautern GmbH

Haidian District

Am Sportplatz 5

Beijing, China 100044

67661 Kaiserslautern

+86 10 8857 7575 Phone

GERMANY

+86 10 8857 7161 Fax

Tel +49-(0)6301-71 14 14

www.trimble.com.cn

Fax +49-06301-32213

 

Africa & Middle East

 

Trimble Export Middle-East

 

P.O. Box 17760

 

JAFZ View, Dubai

 

UAE

 

+971-4-881-3005 Phone

 

+971-4-881-3007 Fax

 

– 20 –

Declarations

We declare, on our sole responsibility, that this product complies with the following directives and standards:

EN 50081-1, EN 61000-6-2, 2004/108/EC. Designation: Laser range meter

Type: QM95

Notice to Our European Union Customers

For product recycling instructions and more information, please go to: www.trimble.com/environment/summary.html

Recycling in Europe

To recycle Trimble WEEE, call: +31 497 53 2430, and ask for the “WEEE associate,” or

mail a request for recycling instructions to: Trimble Europe BV

c/o Menlo Worldwide Logistics Meerheide 45

5521 DZ Eersel, NL

N324

© 2012, Trimble Navigation Limited. All rights reserved. Reorder PN 1213-1220 Rev A (09/12)

– 21 –

– 22 –

– 23 –

Page 2
Image 2
Spectra QM95 Specifications, General Care, Safety And Storage, Transport, Trouble Shooting, Laser Safety, Warranty