Quarterly

1.Deactivate electrical circuit by turning off disconnect switch on rear of tumbler.

2.Perform daily cleaning of accumulated lint.

3.Perform monthly inspection and cleaning of accumulated lint.

4.Clean accumulated lint and other debris from front and back motor air vents.

5.Shut off gas supply at manual gas shut off valve in gas supply line (gas models only). Handle of gas shut off valve should be at 900 angle to gas supply line when in “OFF” position.

Biannually

6.Remove screws holding rear drive guard to back of tumbler.

7.Inspect belts for wear and proper tension (refer to Adjustments section).

8.Reinstall rear drive guard to back of tumbler.

9.Energize electrical circuit to tumbler by turning on electrical disconnect switch on rear of tumbler.

10.Turn on gas supply at manual gas shut off valve in gas supply line (gas models only). Handle of gas shut off valve should be parallel with gas supply line when in “ON” position.

1.Deactivate electrical circuit by turning off disconnect switch on rear of tumbler.

2.Perform daily cleaning of accumulated lint.

3.Perform monthly inspection and cleaning of accumulated lint.

4.Perform quarterly inspection and cleaning of accumulated lint.

5.Remove or open all panels and check accessible bolts, nuts, screws, terminals and fittings for tightness.

6.Shut off gas supply at manual gas shut off valve in gas supply line (gas models only). Handle of gas shut off valve should be at 900 angle to gas supply line when in “OFF” position.

7.Unlock and open service panel and inspect gas connections for evidence of leakage or loose connections.

NOTE: Spraying a mild solution of soap and water on joints will cause bubbles to appear on any leaking connections.

8.Close and securely lock service panel.

9.Open electrical junction box cover and inspect all electrical and grounding connections for security. Tighten any loose electrical connections.

10.Close electrical junction box cover and energize electrical circuit to tumbler by turning on electrical disconnect switch.

11.Turn on gas supply at manual gas shut off valve in gas supply line (gas models only). Handle of gas shut off valve should be parallel with gas supply line when in “ON” position.

58

M412616