Assembly

1.Visually inspect all tapped blade mounting holes for any debris which could cause problems when tightening cap screws.

2.Install blades with rotation arrow on top side and pointing in a clockwise direction.

3.Hold each blade level and tighten the six cap screws just enough to hold the blade level.

4.Do not torque cap screws. Blades must be free to turn in retaining ring to adjust pitch.

The trial pitch angle is the calculated setting for design conditions

Note(water rate, heat load, air density, and brake horsepower). The trial

blade pitch is provided on page 2.

Blade Pitching

 

AIR

STRAIGHT

 

FLOW

BEVEL

EDGE

 

 

 

PROTRACTOR

 

 

ROTATION

 

PITCH ANGLE

 

± 1/4°

 

 

5.Select a position on the fan circumference and rotate each blade to this common location when setting or checking blade pitch. All blades must be pitched with the blade axis pointing in the same direction. Support the blade tip to maintain the proper plane of rotation while setting the fan pitch.

6.Set the pitch angle and torque cap screws for each blade. Set the pitch angle using a straight edge and bevel protractor 2" (51mm) from blade tip as illustrated. Blades should be within ±14° of the desired pitch.After the de- sired pitch is obtained progressively tighten blade cap screws to 30-35 ft·lbƒ (41-47 N·m) torque. A crowfoot wrench may be necessary to torque cap screws that cannot be reached with a socket.

7.Install hub cover using cap screws and resilient washers.

8.Tighten cap screws between 10 and 15 ft·lbƒ (14-20 N·m) torque.

Maintenance

Preventative maintenance will prolong useful life and assure continued trouble-free operation. After the first week of operation and subsequently at six month intervals:

1.Visually inspect the fan for airborne debris damage and corrosive at- tack.

2.Torque blade cap screws.

3.Remove any accumulated scale or dirt.

4. Clear blade drain holes.

3

Page 3
Image 3
SPX Cooling Technologies HP7I user manual Assembly, Maintenance

HP7I specifications

SPX Cooling Technologies HP7I is a prominent cooling solution designed to deliver efficient thermal management in various industrial applications. Engineered with advanced features and technologies, the HP7I is recognized for its robust design and exceptional performance capabilities.

One of the main features of the HP7I is its efficient heat exchange technology. This unit employs a closed circuit cooling system that enhances heat transfer efficiency while minimizing the potential for contamination. The design focuses on optimizing fluid flow, which ensures consistent cooling performance even under varying load conditions. This feature is particularly beneficial in applications where reliable temperature control is critical for operational efficiency.

Another hallmark of the HP7I is its flexible configuration options. The cooling unit can be tailored to meet varying site demands, thanks to its modular design. Whether installed in a compact space or integrated into a larger cooling system, the HP7I's adaptability makes it a preferred choice for engineers and facility managers seeking customizable cooling solutions.

In terms of energy efficiency, the HP7I stands out with its innovative fan technology. The unit is equipped with high-efficiency fans that are designed to consume less power while delivering maximum air flow. This feature not only reduces operational costs but also contributes to a more sustainable cooling solution, aligning with today’s emphasis on energy conservation.

The HP7I also features a durable construction, ensuring longevity and resilience in harsh operating environments. The materials used are selected for their ability to withstand corrosion, wear, and extreme temperatures. This durability minimizes maintenance requirements and extends the lifecycle of the cooling unit, providing long-term value to users.

Ease of maintenance is another significant advantage of the HP7I. The unit's design includes easy access points for inspection and servicing, reducing downtime during routine maintenance. Additionally, SPX incorporates smart technology features that enable remote monitoring, allowing operators to track performance data and receive alerts for potential issues before they escalate.

Moreover, the HP7I is compliant with various industry standards, ensuring reliability and safety in its operation. This compliance, along with its cutting-edge features, makes the HP7I a leading choice for industries such as power generation, petrochemical processing, and manufacturing.

In conclusion, SPX Cooling Technologies HP7I delivers a powerful combination of efficiency, flexibility, and durability, making it an ideal cooling solution for industrial applications. With its advanced heat exchange technology, energy-efficient design, and easy maintenance features, the HP7I sets a benchmark for excellence in thermal management.