6.18.3 CALIBRATING WATER TEMPERATURE SENSOR
If the temperature display is incorrect, it can be
1.Turn the transceiver off.
2.Hold down the [SQL] key, and then turn on the trans- ceiver while still holding down the [SQL] key.
3. “SEt” will appear on the display, indicating that the Menu (“Set”) Mode has been activated.
4. Press the [SQL] key to select the Menu item “04 tEP”.
5. Press the [T] or [S] key to set the difference between HX750S display and the calibrated thermometer.
For example, if the HX750S display shows “68.0 °F” and the (calibrated) thermometer indicates “65.3 °F”, set the temperature offset to
6. Press the [SQL] key to save the new setting, then press the PTT switch to exit to normal operation.
When change the temperature unit (“°FÆ°C” or “°CÆ°F”) via Menu Mode, perform this procedures.
The temperature sensor may not display the correct temperature when the temperature inside the radio is high; for example, while the transmission mode or high receiver audio output.
6.19 ENABLING S.O.S STROBE OPERATION
The S.O.S. STROBE feature utilizes the
1.Hold down the [MEM] key while turning the radio on to activate the emer- gency S.O.S. Strobe. Once the radio comes on, the TX/BUSY LED will flash the Morse Code S.O.S. message repeatedly.
2.The S.O.S. strobe function is interrupted when a signal is received or if the squelch control is turned so audio is heard from the speaker.
3.To disable the S.O.S. strobe function, turn the radio off and back on again.