Stanley Black & Decker BR87 user manual Underwater Model Preventative Maintenance

Models: BR87

1 22
Download 22 pages 9.62 Kb
Page 15
Image 15

CHARGING THE ACCUMULATOR

Figure 2. Charging the Accumulator

UNDERWATER MODEL PREVENTATIVE MAINTENANCE

After each use, the movable portions of the tool that were exposed to water should be flushed with a water displacing oil such as WD40™. Remove any remaining water and debris as follows:

1.Turn the tool upside down (without the tool bit) and spray oil through the drive hex and side holes in the breaker foot assembly to displace any remaining water in the lower piston cavity.

2.Spray oil into the On/Off valve trigger slot area.

3.Dip or spray the entire tool.

4.Cycle the tool hydraulically several times before storing away.

BR87 User Manual ◄ 15

Page 15
Image 15
Stanley Black & Decker BR87 user manual Underwater Model Preventative Maintenance