CHARGING THE ACCUMULATOR
Figure 2. Charging the Accumulator
UNDERWATER MODEL PREVENTATIVE MAINTENANCE
After each use, the movable portions of the tool that were exposed to water should be flushed with a water displacing oil such as WD40™. Remove any remaining water and debris as follows:
1.Turn the tool upside down (without the tool bit) and spray oil through the drive hex and side holes in the breaker foot assembly to displace any remaining water in the lower piston cavity.
2.Spray oil into the On/Off valve trigger slot area.
3.Dip or spray the entire tool.
4.Cycle the tool hydraulically several times before storing away.
BR87 User Manual ◄ 15