RM-100
Professional performance mixer
STANTON MAGNETICS, LLC
info@stantonmagnetics.com
OWNER’S M A N U A L
FA DER CLE A N I N GThe RM-100 faders may need lubrication from time to time. This will extend the
fader life and eliminate any potential damage due to extended heavy usage.
Cleaning Instructions
1. Remove the fader and disconnect the cable coming from the mixer.To remove
the crossfader, unsecrew the outer screws (removing the 2 inner screws will
detach the fader from the fader plate). To remove the line faders, remove all 4
screws.
2. Spray a small amount of cleaner or lubricant into both ends of the fader and
slide the fader back and forth a few times to spread the fluid evenly throughout
the fader.
3. Shake and wipe off excess fluid before re-assembling the fader.
FAD ER R E PL AC E M E N TTo replace the cross or channel faders, follow step 1 of the cleaning instructions.
Replacement parts are available from Stanton or your local Stanton dealer.
CF-RM19 Crossfader
LF-RM19 Line input fader
RF-RM19 Line input rotary (dial) fader
PS-RM19US US Power Supply (110v)
PS-RM19EU European Power Supply (220v)
PS-RM19UK UK only Power Supply (240v)
©2001, Stanton Magnetics, LLC