CONNECTIONS

CONNECTIONS

1.Connect the power cord to the auxiliary power outlet on the rear panel of your amplifier or receiver or to a household AC outlet.

2.Connect the unit output terminals to the PHONO jack of your amplifier or receiver.

Output terminals

 

Amplifier(Receiver)

L (White)

>>

L Channel

R (Red)

>>

R Channel

GND (Spade)

>>

GND

NOTE:

ŸBe sure to connect the ground terminal firmly to the amplifier or receiver.

ŸIf this connection is not made or is loose, a power source "HUM" will result.

OPERATION

1.Rotate the power dial clockwise to turn on the power, the speed indicator and the strobe-illuminator will light up.

2.Place a record on the slip mat, when playing a 45rpm record with a large center hole, place the 45-rpm adaptor on the center spindle.

3.Set the speed to match the record.

4.Remove the stylus protector, release the arm clamp.

5.Press the Start/Stop button, the turntable platter will start to rotate.

6.Move the tonearm over the desired groove.

7.When play is finished, move the tonearm to the arm rest, secure the tonearm with the arm clamp.

8.Press the Start/Stop button to stop the platter rotating, rotate the power dial to turn off the power.

MAINTENANCE

For best results & proper care of your equipment use Stanton Vinyl Cleaner (VC-1) for your records and Stylus Cleaner Kit for styli (SC-4).

Clean the stylus periodically with a soft brush to prevent the accumulation of dust.

When the sound becomes distorted or noisy, check the stylus. If worn out, replace it with a new one.

Any volatile materials such as alcohol, thinner, benzine, etc., may remove the paint or damage the lustre, please avoid.

SPECIFICATIONS

APPLICATION:

This specification applies to the direct drive turntable unit T.60

STANDARD TEST CONDITION:

 

Ambient Temperature

20 +/- 2 degC

Relative Humidity

65% +/- 5%

NOTE: Measurements can be carried out between 5 degC to 35 degC and 45% to 85% relative humidity.

TURNTABLE SECTION:

 

Type

2-speed full manual

Motor

8pole, 2phase,brushless DC motor

Speeds

331/3 and 45rpm

Wow and Flutter

Less than 0.15% WRMS (JIS WTD) with 331/3rpm

Pitch Controls

+/-10%

Starting Torque

More than 1 kgf.cm

Starting Time

Less than 1 sec. with 331/3rpm

Braking Time

Less than 1 sec. with 331/3rpm

Time for Speed Change

Less than 1 sec. from 331/3 to 45 rpm.

 

Less than 1 sec. from 45 to 331/3 rpm.

Audio Output

Phono output