R E S I D E N T I A L
SELECT®
Residential Gas Water Heaters
MODEL
NUMBER
| PEAK |
|
|
|
|
|
|
| DIMENSIONS IN INCHES |
|
| APPROX | ||
| DEMAND |
|
| BTU INPUT | RECOVERY | FOAM |
|
|
|
|
|
|
| |
SERIES | OUTPUT | ENERGY | GALLON | THICK- |
|
|
|
|
|
|
| SHIPPING | ||
|
|
|
|
|
|
|
|
| ||||||
(1st Hour | FACTOR | CAPACITY | PER HOUR | 90°F RISE | NESS | A | B | C | D | E | F | DRAFT WEIGHT | ||
| Rating |
|
| NATURAL† | GALLONS | (Inches) | HOOD | (LBS) | ||||||
|
|
|
|
|
|
|
|
|
|
| OUTLET | |||
| Gallons) |
|
|
|
|
|
|
|
|
|
|
|
|
TALL MODELS
| 200 |
|
|
|
| 41 | 1 | 18 | 13 |
| 138 |
| |||
|
| GS6 50 YBRT 200 | 88 | .58 | 50 | 40,000 | 41 | 1 | 20 | 13 | 8 | 153 |
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| SHORT MODEL |
|
|
|
|
|
|
|
|
|
|
|
|
|
GS6 40 YBRS | 200 |
70 | .59 | 40 | 40,000 | 41 | 1 | 20 | 13 | 8 | 41 | 3 or 4 | 135 |
HIGH EFFICIENCY MODELS
| GS6 40 YOCT | 200 |
| .62 |
| 40,000 | 41 | 2 | 20 | 13 |
| 3 or 4 | 150 |
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| GS6 50 YOCT | 200 | 88 | .62 | 50 | 40,000 | 41 | 2 | 61 |
| 22 | 13 | 8 |
| 3 or 4 | 165 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Recoveries are rounded to nearest gallon. Water Connections – 3/4" male on all models.
External heat trap nipples are factory installed on all models.
† Propane Gas – 37,000 input for
For
When ordering
Flammable Vapor Ignition Resistant Water Heaters
State FVIR design meets or exceeds the American National Standards Institute standards (ANS Z21.10.1) that deal with the accidental or unintended ignition of flammable vapors, such as those emitted by gasoline.
Feature a sealed combustion chamber with air intake filter and a flame arrestor built into the water heater base. In addition, a thermal cutoff (TCO) device, is designed to shut off gas flow to the burner and pilot if
poor combustion is detected.
If flammable vapors accidentally enter the combustion chamber, the arrestor is designed so flames burn off the top surface and can not escape down through the arrestor.
|
|
|
|
|
|
|
| D | |||
|
|
|
|
|
|
| A | ||||
B |
|
|
| D | |
|
|
| |||
|
|
|
|
|
C
A. Industry standard thermocouple
B. Large View Port for easy burner inspection C. 3600 combustion air filter
D. Thermal Cutoff (TCO) with manual reset
CONNECTION
COLD
CONNECTION
E
C
T&P VALVE |
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1/2" GAS |
|
|
|
|
|
|
|
|
|
| A | ||||
|
|
|
|
|
|
|
| B | |||||||
|
|
|
|
|
|
|
|
|
| ||||||
CONNECTION |
|
|
|
|
|
| F |
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
D
For complete information on limited warranties, consult written warranty, or contact the State Customer Care Center,
State Industries, Inc. reserves the right to make product changes or improvements without prior notice.
*Location for optional
Maximum Hydrostatic Working Pressure: 150 PSI.
For more information on Select® contact: State Water Heaters
500 Tennessee Waltz Parkway, Ashland City, TN 37015
800.365.0024
SRGSS02408 | August 2008R |
|
|
|
|