WATTAGE, RECOVERY AND ELECTRICAL CHARACTERISTICS
UPPER | RECOVERY – GALLONS |
| FULL LOAD CURRENT IN | ||||
AND | PER HOUR AT °F RISE |
|
| AMPERES |
| ||
LOWER |
|
|
|
|
|
|
|
ELEMENT | 40°F | 100°F | 140°F |
| 208V | 240V | 480V |
WATTAGE |
| ||||||
|
|
|
|
|
|
| |
|
|
|
|
|
|
| |
AND | POWER | ||||||
1500 | 15 | 6 | 4 |
| 7.2 | 6.3 | 3.1 |
|
|
|
|
|
|
|
|
2000 | 20 | 8 | 5 |
| 9.6 | 8.3 | 4.2 |
|
|
|
|
|
|
|
|
2500 | 25 | 10 | 7 |
| 12.0 | 10.4 | 5.2 |
|
|
|
|
|
|
|
|
3000/3000 | 30 | 12 | 8 |
| 14.4 | 12.5 | 6.3 |
|
|
|
|
|
|
|
|
4000/4000 | 41 | 16 | 11 |
| 19.2 | 16.7 | 8.3 |
|
|
|
|
|
|
|
|
4500/4500 | 46 | 18 | 13 |
| 21.6 | 18.8 | 9.4 |
|
|
|
|
|
|
|
|
5000/5000 | 51 | 20 | 14 |
| 24.0 | 20.8 | 10.4 |
|
|
|
|
|
|
|
|
6000/6000 | 61 | 24 | 17 |
| 28.8 | 25.0 | 12.5 |
|
|
|
|
|
|
| |
SIMULTANEOUS DUAL- | ELEMENT |
| |||||
(Both elements on when | entire tank is cold) |
|
|
| |||
3000/3000 | 61 | 24 | 17 |
| 25.0/14.4* | 21.7/12.5* | 10.8/6.3* |
|
|
|
|
|
|
|
|
4000/4000 | 81 | 32 | 23 |
| 33.3/19.2* | 28.9/16.7* | 14.4/8.3* |
|
|
|
|
|
|
|
|
4500/4500 | 91 | 36 | 26 |
| 37.5/21.6* | 32.5/18.8* | 16.2/9.4* |
|
|
|
|
|
|
|
|
5000/5000 | 101 | 41 | 29 |
| 41.6/24.0* | 36.1/20.8* | 18.0/10.4 |
|
|
|
|
|
|
|
|
6000/6000 | 122 | 49 | 35 |
| N/A | 43.3/25.0* | 21.7/12.5 |
|
|
|
|
|
|
|
|
*Terminal L2 Amperage/Terminals L1 and L3 Amperage
TANK CAPACITY, DIMENSIONS AND WEIGHTS
MODEL | GALLON | NUMBER | DIMENSIONS IN INCHES |
| APPROX | |||
OF |
|
|
|
| SHIPPING | |||
NUMBER | CAPACITY | A | B | C | D | WEIGHT | ||
ELEMENTS | ||||||||
|
| (LBS.) | ||||||
|
|
|
|
|
|
| ||
PCE 6 10MSA | 6 | 1 | 11 | N/A | 35 | |||
|
|
|
|
|
|
|
| |
PCE 10 10MSA | 10 | 1 | 18 | N/A | 54 | |||
PCE 17 10MSA | 15 | 1 | 26 | 18 | N/A | 58 | ||
|
|
|
|
|
|
| ||
PCE 20 10MSA | 20 | 1 | N/A | 73 | ||||
PCE 30 20LSA | 30 | 2 | 8 | 100 | ||||
|
|
|
|
|
|
|
| |
PCE 40 20LSA | 40 | 2 | 24 | 8 | 125 | |||
PCE 50 20LSA | 50 | 2 | 8 | 166 | ||||
|
|
|
|
|
|
| ||
PCE 30 20RTA | 30 | 2 | N/A | 8 | 98 | |||
PCE 40 20RTA | 40 | 2 | N/A | 8 | 113 | |||
|
|
|
|
|
|
| ||
PCE 52 20RTA | 50 | 2 | N/A | 8 | 131 | |||
PCE 66 20RTA | 66 | 2 | N/A | 8 | 176 | |||
|
|
|
|
|
|
|
| |
PCE 82 20RTA | 80 | 2 | 24 | N/A | 8 | 211 | ||
PCE 120 20RTA | 119 | 2 | N/A | 8 | 326 | |||
|
|
|
|
|
|
|
|
HEATING ELEMENT AVAILABILITY
INPUT | 120V | 208V | 240V | 277V | 480V | |
WATTS | ||||||
|
|
|
|
| ||
1500 | YES | YES | YES | YES | NO | |
2000 | YES | YES | YES | YES | NO | |
2500 | YES | YES | YES | YES | YES | |
3000 | YES | YES | YES | YES | YES | |
3500 | NO | NO | YES | NO | NO | |
4000 | NO | YES | YES | YES | YES | |
4500 | NO | YES | YES | YES | YES | |
5000 | NO | YES* | YES* | YES* | YES* | |
5500 | NO | NO | YES | NO | NO | |
6000 | NO | YES** | YES | YES | YES |
*Not available in PCE 10 10MSA, PCE 17 10MSA and PCE 30 20RTA. **A6
PCE 6 10MSA not available above 2500 W. PCE 6 10MSA not available in 480V.
SCESS00106 | August 2008R | Page 2 of 4 | ©2008 State Water Heaters Company |
|
|
|
|
|
|
|
|