R E S I D E N T I A L
SELECT®
Residential Gas Water Heaters
| PEAK |
|
|
|
|
|
|
| DIMENSIONS IN INCHES |
|
| APPROX. | ||
| DEMAND |
|
| BTU INPUT RECOVERY |
|
|
|
|
|
|
|
| ||
MODEL | OUTPUT | ENERGY | GALLON | R |
|
|
|
|
|
|
| SHIPPING | ||
PER HOUR | 90°F RISE |
|
|
|
|
|
| DRAFT | ||||||
NUMBER | (1st Hour FACTOR | CAPACITY | VALUE** | A | B | C | D | E | F | WEIGHT | ||||
| Rating |
|
| NATURAL† | GALLONS |
| HOOD | (LBS) | ||||||
|
|
|
|
|
|
|
|
|
|
|
| OUTLET | ||
| Gallons) |
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
TALL MODELS |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
GS6 30 YBRT | 66 | 0.62 | 28 | 40,000 | 41 | 8 | 16 | 8 | 3 or 4 | 112 | ||||
GS6 40 YBRT | 71 | 0.59 | 38 | 40,000 | 39 | 8 | 8 | 3 or 4 | 126 | |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
GS6 50 YBRT | 91 | 0.58 | 50 | 40,000 | 41 | 8 | 20 | 8 | 3 or 4 | 160 | ||||
SHORT MODELS |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
GS6 30 YBRS | 66 | 0.61 | 30 | 40,000 | 40 | 8 | 8 | 3 or 4 | 122 | |||||
GS6 40 YBRS | 71 | 0.59 | 40 | 40,000 | 41 | 8 | 20 | 8 | 41 | 3 or 4 | 139 | |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
GS6 50 YBRS | 80 | 0.58 | 50 | 40,000 | 41 | 16 |
| 24 |
| 8 |
| 3 or 4 | 168 |
Recoveries are rounded to nearest gallon.
Water Connections – 3/4" male on all models except GS6 50 YBRT (3/4" female). External heat trap nipples are supplied on all models except GS6 50 YBRT.
† Propane Gas – 37,000 BTU models.
**All models are
For
When ordering
Flammable Vapor Ignition Resistant C3 Technology® Water Heaters
Corderite Combustion Containment (C3) design meets American National Standards Institute standards (ANS
Covered by four U.S. patents, C3 Technology gas water heaters feature a sealed combustion chamber with air intake screen and a fireproof Corderite flame arrestor built into the water heater base. In addition, a Thermal Cutoff (TCO) device, integral with the thermocouple, is designed to shut off gas flow to the burner and pilot if poor combustion is detected.
In the unlikely event that flammable vapors accidentally enter the combustion chamber, the Corderite flame arrestor is designed so any flames burn off the top surface and cannot escape down through the arrestor.
A.
B.View port for easy inspection of burner inside sealed combustion chamber
For complete information on limited warranties, consult written warranty, or contact the State Customer Care Center,
State Industries, Inc. reserves the right to make product changes or improvements without prior notice.
For more information on Select® contact: State Water Heaters
500 Tennessee Waltz Parkway, Ashland City, TN 37015
800.365.0024
SRGSS01206 | January 2008R |
*Location for optional
if ordered from factory. To order, add “G” to model number (GS6 40 YBRTG).