32
1. With the 5 gallon Up-N-Down container in the vertical position,
unscrew the plastic vent cap in the handle and pierce the
plastic membrane over the vent boss under the cap to allow
the container to vent.
Note: If your container does not have the vent cap and vent
boss, drill a 3/16" hole in the handle. When you have finished
deliming you will be able to plug this drilled vent with the
stainless steel screw that is supplied with the kit.
2. Remove the container's cap and cut the plastic membrane
located in the 3/4" IPT opening in the cap. Take care to not
damage the threads.
3. Find the 3/4" male adapter, apply teflon tape to the threaded
end and screw it into the 3/4" IPT opening in the cap.
4. Put cap with male adapter back on the container and slide
3/4" hose over end of male adapter and fasten in place using
hose clamp provided.
Delime using Flo-Jug Method
5. Slide the hose clamp over end of hose and slide hose over
the male adapter in the water heater drain opening and
secure in place using hose clamp.
6. Lift container to the "Pour" Position, see Figure 9, being careful
to keep the vent in the handle above the liquid level and pour
the UN•LIME into the heater.
7. Lower container, you may have to place the container on its
empty carton to prevent the UN•LIME from flowing back into
the container.
8. Let UN•LIME remain in the heater for 5 minutes and then
lower the container to the "Drain" Position, see Figure 9.
9. Deliming activity is indicated by foaming on the surface of the
UN•LIME. If there is deliming activity, repeat steps 6 thru 8.
Normally, lime removal will be completed within one hour. Severe
build-up of lime may take longer than an hour to complete
descaling.
Note: To check UN•LIME for continued use, place some scale or
white chalk in a glass with a small amount of UN•LIME. If the
material is vigorously dissolved by the UN•LIME, it can be reused;
if not, the UN•LIME should be replaced.

TROUBLESHOOTING

IGNITION MODULE SYSTEM

Before calling your service agent, the following checklist should
be examined to eliminate obvious problems from those requiring
replacement or servicing.
Check that “main manual gas shutoff valve” is fully open
and that gas service has not been interrupted.
Check that after following the appliance OPERATING
INSTRUCTIONS, the “Top Knob” of the appliance gas valve
is in “ON” position.
Check electrical supply to the appliance for possible blown
(or tripped) fusing or power interruption.
Is the water temperature in tank below the thermostat dial
setting on the appliance thermostat (calling for heat)?
It is possible that the high limit (E.C.O.) has functioned to
shut off the appliance. See FEATURES — Water Temperature
Control for reset procedure. Contact your serviceman if
limit continues to function to shut off appliance.
SERVICE
The installer may be able to observe and correct certain problems
which may arise when the unit is put into operation. HOWEVER,
it is recommended that only qualified servicemen, using
appropriate test equipment, be allowed to service the heater.
As preliminary step, check wiring against diagram, check for
grounded, broken or loose wires. Check all wire ends to be
sure that they are making good contact.

ELECTRICAL SERVICING

CAUTION
LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN
SERVICING CONTROLS. WIRING ERRORS CAN CAUSE
IMPROPER AND DANGEROUS OPERATION.
VERIFY PROPER OPERATION AFTER SERVICING.

REPLACEMENT PARTS

Replacement parts may be ordered through State dealers,
authorized servicers or distributors. Refer to the Yellow Pages
for where to call or contact the State Water Heaters When ordering
parts be sure to state the quantity, part number and description
of the item(s) including the complete model and serial number
as it appears on the product. Refer to the part’s list for more
information.