HOW DO YOU TEST YOUR PFD USING THE ORAL INFLATOR?

1.To test your inflatable PFD, you will not need any spare parts.

2.Remove the CO2 cylinder to prevent inadvertent activation of the manual inflation which could potentially damage the PFD. Inspect the threaded end to confirm it’s un-used.

3.Put on the PFD.

4.Get into shallow water, just deep enough that you can stand with head above the surface.

5.If you are a weak or non-swimmer, inflate the PFD partially so that you are supported well enough to complete inflation without touching bottom, either orally or manually. Note this level of inflation because it is the minimum needed for you to safely use this inflatable PFD.

6.Fully inflate the PFD using the oral inflator.

7.See if the PFD will float you on your back or slightly back of vertical. In a relaxed floating position, verify that your mouth is well above the water’s surface. Note the effect of where you hold your legs on how you float.

8.Get out of the water and remove the PFD. Completely deflate the PFD using the oral inflator.

9.Let the PFD dry thoroughly. REARM AND REPACK the PFD in accordance with the manufacturer’s instructions. Refer to Pages 11, 12 and 13.