Stearns Safety & Survival 1189 manual HOW do YOU Test Your PFD Using Manual INFLATOR?

Models: 1189

1 20
Download 20 pages 54.18 Kb
Page 13
Image 13

HOW DO YOU TEST YOUR PFD USING THE

MANUAL INFLATOR?

1.To test your inflatable PFD, you will need:

Your fully armed PFD, and

Rearming kit approved for your PFD.

2.Put on the PFD.

3.Actuate the inflation system by jerking firmly downward on the pull tab. The PFD should fully inflate within 5 seconds.

4.Get into shallow water, just deep enough that you can stand with your head above the surface.

5.See if the PFD will float you on your back or just slightly back of vertical. In a relaxed floating position, verify that your mouth is well above the water's surface. Note the effect of where you hold your legs on how you float.

6.Get out of the water and remove the PFD. Remove the used CO2 from the PFD inflator. Completely deflate the PFD using the oral inflator.

7.Let the PFD dry thoroughly. REARM mode and REPACK the PFD in accordance with the manufacturer's instructions (refer to Pages 19 and 20).

13

Page 13
Image 13
Stearns Safety & Survival 1189 manual HOW do YOU Test Your PFD Using Manual INFLATOR?, Your fully armed PFD