CO2 Cylinder
Step 2
Sensor Ring
Step 3
Bayonet |
Tabs |
Step 4 |
Service Indicator
Step 5
Note: Right and Left hand models pictured above. Your inflator will look like either the left or right image.
DISASSEMBLY
(see figure)
Step 1: Unpack or open the life vest so that the manual inflator is visible.
Step 2: Remove gas CO2 cylinder by rotating cylinder counterclockwise then pull out. Discard cylinder.
REARMING
Note: Rearming must follow the sequence below.
Step 3: Check the new cylinder to be sure it has sensor ring attached.
Step 4: Install new cylinder by engaging bayonet tabs in housing, pushing in then turning clockwise 1/8 turn to a full stop.
WARNING: PFD WILL ONLY INFLATE IF
CYLINDER IS TURNED TO FULL STOP.
Step 5: Check to be sure service indicator is green.
Service Indicator
If green, unit is operable.
If red, stop and service unit.
16 | print run id |
|