Motor does not start.

-

No power supply.

- Check fuses.

 

 

 

-

Mains cable defective.

- Have these checked (electrician).

 

 

 

-

Machine overloaded.

- Overload protection triggered Turn On-

 

 

 

 

 

Off switch to “0” and let machine cool

 

 

 

 

 

down.

 

 

 

 

 

 

 

 

Motor hums but does not

-

Cutting roller blocked.

- Turn On-Off switch to left, then switch

 

 

start.

 

 

machine off and remove shredding ma-

 

 

 

 

 

terial. If the blockage cannot be re-

 

 

 

 

 

moved immediately switch the On-Off

 

 

 

 

 

switch between cutting and reverse a

 

 

 

 

 

number of times until the cutting roller

 

 

 

 

 

runs free.

 

 

 

-

Capacitor faulty.

- Bring machine to manufacturer or au-

 

 

 

 

 

thorised workshop for repair.

 

 

 

 

 

 

 

 

Shredding material is not

-

Incorrect switch position.

- Turn On-Of switch to correct position.

 

 

drawn into the shredder.

- Shredding material caught in

- Turn On-Off switch to left to release

 

 

 

 

 

 

 

funnel.

shredding material, remove any dirt.

 

 

 

- Shredding material to soft or

- Push down with a branch and shred.

 

 

 

 

wet.

- Adjust shaving plate as described in

 

 

 

 

 

 

 

 

-

Cutting roller worn.

“Adjusting the shaving plate”, replace

 

 

 

 

 

cutting roller if heavily worn.

 

 

 

 

 

 

 

 

Shredding material not

-

Incorrect setting of shaving

- Adjust shaving plate, if this cannot be

 

 

cut cleanly.

 

plate.

adjusted it has to be replaced by the

 

 

 

 

 

customer service department.

 

 

 

 

 

 

 

 

Device starts but blocks

-

Extension cable too long or

- Extension cable at least 1.5 mm², max-

 

 

under as slight load and

 

cross-section to small Socket

imum 25 m long. If a longer cable is

 

 

switches off via protective

 

too far from mains supply

used, minimum cross-section 2.5 mm².

 

 

motor switch.

 

and cross-section of mains

 

 

 

 

 

cable too small.

 

 

 

 

 

 

 

 

 

 

 

 

 

 